DS1855E-050+ Maxim Integrated Products, DS1855E-050+ Datasheet - Page 8

IC RES TEMP-CNTRL 10/50K 14TSSOP

DS1855E-050+

Manufacturer Part Number
DS1855E-050+
Description
IC RES TEMP-CNTRL 10/50K 14TSSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS1855E-050+

Taps
100, 256
Resistance (ohms)
10K, 50K
Number Of Circuits
2
Temperature Coefficient
750 ppm/°C Typical
Memory Type
Non-Volatile
Interface
I²C, 2-Wire Serial
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
14-TSSOP
Resistance In Ohms
10K and 50K
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
DS1855
2-WIRE SERIAL PORT OPERATION
The 2-wire serial port interface supports a bidirectional data transmission protocol with device
addressing. A device that sends data on the bus is defined as a transmitter, and a device receiving data is
defined as a receiver. The device that controls the message is called a “master.” The devices that are
controlled by the master are “slaves.” The bus must be controlled by a master device that generates the
serial clock (SCL), controls the bus access, and generates the START and STOP conditions. The DS1855
operates as a slave on the two-wire bus. Connections to the bus are made via the open-drain I/O lines,
SDA and SCL. The following I/O terminals control the 2-wire serial port: SDA, SCL, A0, A1, A2.
Timing diagrams for the 2-wire serial port can be found in Figures 2 and 3. Timing information for the 2-
wire serial port is provided in the AC Electrical Characteristics Table for 2-wire serial communications.
The following bus protocol has been defined:
1. Data transfer may be initiated only when the bus is not busy.
2. During data transfer, the data line must remain stable whenever the clock line is HIGH. Changes in
the data line while the clock line is HIGH will be interpreted as control signals.
Accordingly, the following bus conditions have been defined:
Bus not busy: Both data and clock lines remain HIGH.
Start data transfer: A change in the state of the data line from HIGH to LOW while the clock is HIGH
defines a START condition.
Stop data transfer: A change in the state of the data line from LOW to HIGH while the clock line is
HIGH defines the STOP condition.
Data valid: The state of the data line represents valid data when, after a START condition, the data line
is stable for the duration of the clock signal’s HIGH period. The data on the line can be changed during
the clock signal’s LOW period. There is one clock pulse per bit of data. Figures 2 and 3 detail how data
transfer is accomplished on the 2-wire bus. Depending on the state of the R/W bit, two types of data
transfer are possible.
Each data transfer is initiated with a START condition and terminated with a STOP condition. The
number of data bytes transferred between START and STOP conditions is not limited and is determined
th
by the master device. The information is transferred byte-wise and each receiver acknowledges with a 9
bit.
A regular mode (100kHz clock rate) and a fast mode (400kHz clock rate) are defined within the bus
specifications. The DS1855 works in both modes.
Acknowledge: Each receiving device, when addressed, is obliged to generate an acknowledge after the
reception of each byte. The master device must generate an extra clock pulse, which is associated with
this acknowledge bit.
A device that acknowledges must pull down the SDA line during the acknowledge clock pulse in such a
way that the SDA line is a stable LOW during the HIGH period of the acknowledge-related clock pulse.
Of course, setup and hold times must be taken into account. A master must signal an end of data to the
slave by not generating an acknowledge bit on the last byte that has been clocked out of the slave. In this
case, the slave must leave the data line HIGH to enable the master to generate the STOP condition.
8 of 8