MC68340AG16VE Freescale Semiconductor, MC68340AG16VE Datasheet - Page 198

no-image

MC68340AG16VE

Manufacturer Part Number
MC68340AG16VE
Description
IC MPU 32BIT 16MHZ 144-LQFP
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of MC68340AG16VE

Processor Type
M683xx 32-Bit
Speed
16MHz
Voltage
3.3V
Mounting Type
Surface Mount
Package / Case
144-LQFP
Controller Family/series
68K
Core Size
32 Bit
No. Of I/o's
16
Cpu Speed
16MHz
No. Of Timers
2
Embedded Interface Type
UART
Digital Ic Case Style
LQFP
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC68340AG16VE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Freescale Semiconductor, Inc.
Bus operation in progress at the time of a fault is conveyed by the SSW.
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
TP
MV
0
TR
B1
B0
RR
RM
IN
RW
LG
SIZ
FUNC
The bus error stack frame is 12 words in length. There are three variations of the frame,
each distinguished by different values in the SSW TP and MV fields.
An internal transfer count register appears at location SP + $14 in all bus error stack
frames. The register contains an 8-bit microcode revision number, and, for type III faults,
an 8-bit transfer count. Register format is shown in Figure 5-14.
15
8 7
0
MICROCODE REVISION NUMBER
TRANSFER COUNT
Figure 5-14. Internal Transfer Count Register
The microcode revision number is checked before a bus error stack frame is restored via
RTE. In a multiprocessor system, this check ensures that a processor using stacked
information is at the same revision level as the processor that created it.
The transfer count is ignored unless the MV bit in the stacked SSW is set. If the MV bit is
set, the least significant byte of the internal register is reloaded into the MOVEM transfer
counter during RTE execution.
For faults occurring during normal instruction execution (both prefetches and non-MOVEM
operand accesses) SSW TP, MV = 00. Stack frame format is shown in Figure 5-15.
Faults that occur during the operand portion of the MOVEM instruction are identified by
SSW TP, MV = 01. Stack frame format is shown in Figure 5-16.
When a bus error occurs during exception processing, SSW TP, MV = 10. The frame
shown in Figure 5-17 is written below the faulting frame. Stacking begins at the address
pointed to by SP – 6 (SP value is the value before initial stacking on the faulted frame).
The frame can have either four or six words, depending on the type of error. Four-word
stack frames do not include the faulted instruction PC (the internal transfer count register
is located at SP
$10 and the SSW is located at SP
$12).
The fault address of a dynamically sized bus cycle is the address of the upper byte,
regardless of the byte that caused the error.
MOTOROLA
MC68340 USER’S MANUAL
5- 61
For More Information On This Product,
Go to: www.freescale.com