PKU5310ESI Ericsson Power Modules, PKU5310ESI Datasheet - Page 17

DC/DC Converters & Regulators 33W 3.3V OUT 10A 33.02x22.86x7.50 mm

PKU5310ESI

Manufacturer Part Number
PKU5310ESI
Description
DC/DC Converters & Regulators 33W 3.3V OUT 10A 33.02x22.86x7.50 mm
Manufacturer
Ericsson Power Modules
Series
PKU-Er
Datasheet

Specifications of PKU5310ESI

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
EMC Specification
Conducted EMI measured according to EN55022, CISPR 22
and FCC part 15J (see test set-up). See Design Note 009 for
further information. The fundamental switching frequency is
285 kHz for PKU 5310E PI, PKU 5311E PI, and PKU 5313E
PI. For PKU 5315E PI it is 315 kHz.
Conducted EMI Input terminal value (typ)
EMI without filter @ V
External filter (class B)
Required external input filter in order to meet class B in
EN 55022, CISPR 22 and FCC part 15J.
EMI with filter @ V
E
Prepared (also subject responsible if other)
MICOSPE
Approved
EAB/FJB/GMF (Natalie Johansson)
PKU 5000E series
DC/DC converters, Input 18-72 V, Output up to 10 A/35 W
I
= 53 V, max I
I
= 53 V, max I
O
.
O
.
Filter components:
C1,2 = 2.2 μF
C3 = 100 μF
C5,6 = 10 nF, 2kV
L1 = 1.47mH
Checked
MICMALE
Test set-up
Layout recommendations
The radiated EMI performance of the Product will depend on
the PCB layout and ground layer design. It is also important to
consider the stand-off of the product. If a ground layer is used,
it should be connected to the output of the product and the
equipment ground or chassis.
A ground layer will increase the stray capacitance in the PCB
and improve the high frequency EMC performance.
Output ripple and noise
Output ripple and noise measured according to figure below.
See Design Note 022 for detailed information.
Output ripple and noise test setup
Ericsson Internal
PRODUCT SPECIFICATION
No.
3/1301-BMR 6600 Uen
Date
2009-02-20
Technical Specification
EN/LZT 146 391 R4B May 2009
© Ericsson AB
Rev
A
Reference
1 (5)
17