AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
It is the responsibility of the machine designer, controls engineer, machine builder and/or maintenance electrician to apply and maintain
this product in full compliance with all applicable regulations and standards. The product can provide the required safeguarding function
only if it is properly installed, properly operated, and properly maintained. This manual attempts to provide complete installation, opera-
tional, and maintenance instruction. Reading the manual completely is highly recommended. Please direct any questions regarding the
application or use of the product to a Banner Engineering Applications Engineer at the locations listed in this document.
U.S. Application Standards
ANSI B11 Standards for Machine Tools, Safety of Machinery, General Requirements, and Risk Assessment
ANSI NFPA 79 Electrical Standard for Industrial Machinery
ANSI/RIA R15.06 Safety Requirements for Industrial Robots and Robot Systems
ANSI/PMMI B155.1 Package Machinery and Packaging-Related Converting Machinery — Safety Requirements
International/European Standards
ISO 12100-1 & -2 (EN 292-1 & -2) Safety of Machinery – Basic Concepts, General Principles for Design
IEC 60204-1 Electrical Equipment of Machines Part 1: General Requirements
IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems
ISO 62061 Functional Safety of Safety-Related Electrical, Electronic and Programmable Control Systems
Original Instructions
P/N 64137 F
WARNING: . . . User Responsibility
The user is responsible for ensuring that all local, state, and national laws, rules, codes, and regulations relating to
the use of this product in any particular application are satisfied. Extreme care is urged that all legal requirements have
been met and that all installation, operation, and maintenance instructions contained in the product documentation are fol-
lowed.
Important . . . Read This Before Proceeding!
• Diverse-redundant microcontrollers
• Monitors two Banner STB Self-Checking Optical Touch Buttons, or two mechanical
• Two redundant, forced-guided (mechanically linked) output contacts rated at 6 A
• Feedback input monitors external machine control elements
• 5 indicator LEDs for Power, Fault, Input 1, Input 2 and Output
• 24V ac/dc operation
• DIN-rail-mountable 22.5 mm-wide housing with removable terminal blocks
• 500 ms (max.) simultaneity requirement for touch-/push button operation
push buttons
AT-FM-10K Two-Hand Control Module
DUO-TOUCH® SG, for use with two actuating devices
10/7/2010

Related parts for AT-FM-10K

AT-FM-10K Summary of contents

Page 1

... IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems ISO 62061 Functional Safety of Safety-Related Electrical, Electronic and Programmable Control Systems P/N 64137 F AT-FM-10K Two-Hand Control Module DUO-TOUCH® SG, for use with two actuating devices • Diverse-redundant microcontrollers • Monitors two Banner STB Self-Checking Optical Touch Buttons, or two mechanical push buttons • ...

Page 2

... Document Center: http://www.document-center.com/home.cfm Banner Enginering Corp. herewith declares that AT-FM-10K Two-Hand Control Module for industrial control is in conformity with the provisions of the Machinery Directive (Directive 98/37/EEC), and all essential Health and Safety Requirements have been met. Download the complete EC Declaration of Conformity as a PDF file at A DUO-TOUCH SG Two-Hand Control Safety Module (the “ ...

Page 3

... AT-FM-10K Two-Hand Control Module The Duo-Touch SG® Two-Hand Control Kit system complies with: • Two-hand control and Control Reliability requirements per OSHA 29CFR1910.217, ANSI NFPA 79, ANSI B11.19, and ANSI/RIA R15.06, • Type IIIC requirements of ISO 13851 (EN 574) Safety of Machinery – Two-Hand Control Devices, and • ...

Page 4

... This may result in exposure to a hazard. 4 Power Feedback Loop* SW1 SW2 Output < 0.5 s < 0.5 s > 0.5 s Figure 2. Model AT-FM-10K timing logic Mechanical Installation www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module Feedback Open SW1 tied down SW2 tied down P/N 64137 F ...

Page 5

... AT-FM-10K Two-Hand Control Module CAUTION Install Hand Controls to Prevent Accidental Actuation Total protection for the two-hand control system from “defeat” is not possible. However, the user is required by OSHA reg- ulations to arrange and protect hand controls to minimize possibility of defeat or accidental actuation. Each actuating device requires a normally open and a normally closed (e.g., Form C or SPDT) hard contact, each capable of reliably conducting 24V dc (nominal) ...

Page 6

... C = the added distance due to depth penetration factor: 250 mm, per ISO 13855. The ISO 13855 “C” factor can be reduced the risk of encroachment is eliminated, but the safety distance must always be 100 mm or greater. NOTES: 6 Formula for EU-Certified Installations The formula used to calculate the minimum safety distance (S) from the nearest actuator to the danger zone is www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module P/N 64137 F ...

Page 7

... If hand controls have metal housings, the housings must be connected to protective earth ground. If STB Touch Buttons with PNP outputs are used, the entire STB/AT-FM-10K system must be supplied with 24V dc. Electronic actuation devices, including STB Touch Buttons, must share the same voltage supply with the Safety Module. ...

Page 8

... MPCE2 MPCE1 Y2 short-circuited suppressor will create an unsafe L2/–V dc condition which could result in serious injury death. MPCE 14 1 MPCE www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module STB1 Logic + – Blue Brown 24V AT-FM-10K White S12 Y1 S11 (1) Black ...

Page 9

... AT-FM-10K Two-Hand Control Module Connection to the Guarded Machine WARNING Interfacing MSCs NEVER wire an intermediate device(s) (e.g., PLC, PES, PC) between the Safety Module outputs and the Master Stop Control Element it switches in such a manner that in the event of a failure there is a loss of the safety stop com- mand such a manner that the safety function can be suspended, overridden, or defeated, unless accomplish- ed with the same or greater degree of safety ...

Page 10

... Attempts to use the guarded machine under such conditions could result in serious bodily injury or death. 1. Verify that all point-of-operation guards are in place and operating properly. 10 Initial Checkout Procedure Daily Checkout Procedure www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module P/N 64137 F ...

Page 11

... AT-FM-10K Two-Hand Control Module 2. Verify that the two actuating devices must be simultaneously engaged to actuate the machine. 3. For single-cycle machines: Verify that maintained engagement of the two actuating devices results in only one machine cycle. For part-revolution clutch machinery: Verify that release of either actuating device results in the immediate arrest of the ma- chine motion ...

Page 12

... Minimum: Maximum: 15V ac/dc 250V ac / 24V dc resistive 30 mA ac/dc 0.45 W (0.45 VA) 15V ac/dc 250V ac / 24V dc resistive 30 mA ac/dc IEC 60947-5-1; AC15: 230V ac DC-13: 24V dc 0.45 W (0.45 VA) www.bannerengineering.com - tel: 763-544-3164 AT-FM-10K Two-Hand Control Module —— —— —— P/N 64137 F ...

Page 13

... AT-FM-10K Two-Hand Control Module Simultaneity Monitoring Period ≤ 500 milliseconds Status Indicators 4 green LED indicators: Power ON, Input 1 energized, Input 2 energized, Output 1 red LED indicator: Fault Construction Polycarbonate housing. Rated IEC IP20 Mounting Mounts to standard 35 mm DIN rail track. Safety Module must be installed inside an enclosure rated NEMA 3 (IEC IP54), or better ...

Page 14

... This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either AT-FM-10K Two-Hand Control Module www.bannerengin- brasil@banner- sensors@bannerengineering ...