AT-FM-10K BANNER ENGINEERING, AT-FM-10K Datasheet - Page 3

no-image

AT-FM-10K

Manufacturer Part Number
AT-FM-10K
Description
Control Module, Two Hand; Solid State (NPN, PNP), Relay (Auxiliary N.C.); 200 W
Manufacturer
BANNER ENGINEERING
Type
Safetyr
Datasheets

Specifications of AT-FM-10K

Brand/series
Duo-Touch
Contact Form
SPDT-NO/NC
Dimensions
22.5mmW×84mmH×118mmD
Enclosure Rating
IP20
Indicator
4 Green LED, 1 Red LED
Ip Rating
IP20
Material, Casing
Polycarbonate
Mounting
DIN Rail
Mounting Type
DIN Rail
Number Of Outputs
4
Output Type
Digital/Relay
Power Consumption
200 W
Primary Type
Controller
Standards
cULus, cCSAus, CE
Temperature, Operating
0 to +50 °C
Voltage, Supply
24 VDC
Coil Voltage Vac Nom
24V
Coil Voltage Vdc Nom
24V
Contact Current Max
6A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
24V
Contact Configuration
SPST-NO
No. Of Poles
1
Lead Free Status / Rohs Status
RoHS Exempt Product
For Use With
Two-Hand Control
The Duo-Touch SG® Two-Hand Control Kit system complies with:
The Safety Module’s output signal consists of two sets of redundant, forced-guided (mechanically linked) contacts (see wiring diagrams).
Circuitry within the Safety Module monitors these internal contacts and prevents an output signal from occurring if a fault is detected. A
feedback loop is offered for monitoring the status of the machine control elements.
LED Indicators
Module Operation
The Two-Hand Control Safety Module may be used as an initiation device for most powered machinery when machine cycling is control-
led by a machine operator.
Using a two-hand control system makes the operator a “hostage” while the hazard is present, thus limiting or preventing exposure to the
hazard. The two-hand control actuators must be located in a way that hazardous motion is completed or stopped before the operator can
release one or both of the buttons and reach the hazard (see Separation Distance).
The Safety Module’s safety inputs are used to monitor the actuation of the hand controls to comply with the functionality of Type III
requirements of IEC60204-1 and ISO 13851 (Type IIIa/Cat 4) and the requirements of ANSI NFPA79 and ANSI B11.19 for two-hand
control, which include:
Internal Fault (red)
Figure 1. Status indicators and terminal locations
AT-FM-10K Two-Hand Control Module
P/N 64137 F
• Two-hand control and Control Reliability requirements per OSHA 29CFR1910.217, ANSI NFPA 79, ANSI B11.19, and ANSI/RIA
• Type IIIC requirements of ISO 13851 (EN 574) Safety of Machinery – Two-Hand Control Devices, and
• Safety-related applications up to Category 4 PL e, per EN ISO 13849-1 and SIL3 per IEC 61508 and IEC 62061.
• Concurrent (simultaneous) actuation by both hands within a 500 ms time frame
• Where this time limit is exceeded, a requirement that both hand controls must be released before operation is initiated
• Continuous actuation during hazardous condition
• Cessation of hazardous condition if either hand control was released
• Release and re-actuation of both hand controls to re-initiate the hazardous motion or condition (i.e., “anti-tie down”)
• The appropriate performance level of the safety-related function (e.g., Control Reliability, Category/Performance Level, or SIL) as
Input 1 Status
Input 2 Status
R15.06,
Output Status
determined by a risk assessment or the applicable regulation and standards.
Power ON
(green)
(green)
(green)
(green)
CAUTION: . . . Not an Anti-Repeat Control Device
Anti-repeat control is not a function of this Two-Hand Control Safety Module. The user of this device must provide a
suitable means of accomplishing anti-repeat control for any single-stroke or single-cycle machine.
A1 13 23 Y1
Output
Y2 14 24 A2
Power
A1
Y2
Fault
S12
S23
S12 S11 S13
In 1
In 2
S23 S21 S22
13
14
S11
S21
AT-FM-10K
23
24
13
14
Machine
Safety
23
24
S13
S22
Y1
A2
K1
K2
www.bannerengineering.com - tel: 763-544-3164
Power ON
Fault
Input 1 Status
Input 2 Status
Output Status
LED
Power is applied
Simultaneity is
not met or
External wiring
fault
Touch button is
activated
Both relays (K1
and K2) are
energized
ON
No power
Button is not ac-
tivated
OFF
Internal fault
condition is de-
tected
External wiring
fault is detected
Feedback error
Flashing
3