VQZ2121-5YZ1-N7T SMC Corporation, VQZ2121-5YZ1-N7T Datasheet - Page 72

no-image

VQZ2121-5YZ1-N7T

Manufacturer Part Number
VQZ2121-5YZ1-N7T
Description
Solenoid Valve, 5 port, body ported, 2 position sngl, 24VDC, DIN, 1/4 port
Manufacturer
SMC Corporation
Type
Solenoidr
Datasheet

Specifications of VQZ2121-5YZ1-N7T

Brand/series
VQZ Series
Configuration
2-Position Single
Number Of Ports
5
Primary Type
Solenoid Valve
Size, Port
1⁄4"
Voltage, Coil
24 VDC
Operating Pressure Range
15-100 PSI (30-100 PSI For Three Position Valves)
1. Crimping of lead wires and sockets
2. Attaching and detaching sockets with lead
Crimping tool part no. DXT170-75-1
Back page 3
Not necessary if ordering the lead wire pre-connected model.
Strip 3.2 to 3.7 mm at the end of the lead wires, insert the
ends of the core wires evenly into the sockets, and then crimp
with a crimping tool. When this is done, take care that the cov-
erings of the lead wires do not enter the core wire crimping
area.
wires
Attaching
Insert the sockets into the square holes of the connector ( ,
indication), and continue to push the sockets all the way in un-
til they lock by hooking into the seats in the connector. (When
they are pushed in, their hooks open and they are locked auto-
matically.) Then, confirm that they are locked by pulling lightly
on the lead wires.
Detaching
To detach a socket from a connector, pull out the lead wire
while pressing the socket’s hook with a stick having a thin tip
(approx. 1 mm). If the socket will be used again, first spread
the hook outward.
Socket
Caution
Core wire
crimping area
Socket
Hook
Lead Wire Connection
Series
Specific Product Precautions 2
Be sure to read this before handling.
For Safety Instructions and Common Precautions, refer to “Precautions for Handling
Pneumatic Devices” (M-03-E3A).
Crimping area
Core wire
Insulation
Lead wire
VQZ
0.2 to 0.33 mm
Max. cover diameter: ø1.7 mm
Lead wire
Connector
2
1. When replacing a conventional type valve
[Conventional]
[New]
with a new type for maintenance or other
reasons, a “conversion connector assem-
bly” is necessary to convert the connector
from 3 terminals to 2 terminals and must be
ordered separately. (When ordering, refer to
the below part nos.)
For pilot valves, there is no compatibility between the conven-
tional type and new type. When replacing a pilot valve, be sure
to confirm whether it is the new type or the conventional type.
Caution
Valve and Pilot Valve Replacement
Adapter plate
(Blue)
Manual override
Pilot valve
(V111)
1
2
3
4
Adapter plate
VQZ1000V-85-„A
Manual override
Pilot valve
(VQ111)
(Orange)
Conversion connector assembly
24/12 VDC
100 VAC
200 VAC
Other AC voltages
Coil voltage

Related parts for VQZ2121-5YZ1-N7T