VXD2140-04T-3CR1 SMC Corporation, VXD2140-04T-3CR1 Datasheet - Page 13

no-image

VXD2140-04T-3CR1

Manufacturer Part Number
VXD2140-04T-3CR1
Description
Process Solenoid Valve, 2 port, pilot operated, 1/2 port, NC, 110VAC, conduit
Manufacturer
SMC Corporation
Type
Pilot Operatedr
Datasheet

Specifications of VXD2140-04T-3CR1

Brand/series
VX Series
Number Of Ports
2
Primary Type
Solenoid Valve
Size, Port
1⁄2" NPTF
Voltage, Coil
110 VAC
Enclosure
Equivalent to IP65
Series
Model/Valve Specifications
Operating Fluid and Ambient Temperature
Note 1) Since the AC/Class B coil (with a full-wave rectifier) uses a rectifying
Note 2) With no freezing
3
Thread
Thread
Normally closed (N.C.)
Flange
Normally open (N.O.)
Flange
Power source
For Water
Port size
Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for terminal type respectively.
• Refer to “Glossary of Terms” on front matter 10, for details on the max. operating pressure differential and the max. system pressure.
Port size
Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for terminal type respectively.
• Refer to “Glossary of Terms” on front matter 10, for details on the max. operating pressure differential and the max. system pressure.
circuit, the fluid and ambient temperature are the same as the DC
specifications.
AC
DC
3 8
1 2
3 4
3 8
1 2
3 4
1 4
1 (25A)
1 (25A)
32A
40A
50A
32A
40A
50A
(10A)
(15A)
(20A)
(10A)
(15A)
(20A)
VXD21/22/23
(8A)
Operating fluid temperature (°C)
Nil
1 to 60
1 to 40
Orifice size
Orifice size
, G, H
Solenoid valve option
(mmø)
(mmø)
10
10
15
10
15
20
25
35
40
50
15
20
25
35
40
50
VXD2130-02
VXD2130-03
VXD2140-03
VXD2130-04
VXD2140-04
VXD2150-06
VXD2260-10
VXD2270-32
VXD2380-40
VXD2390-50
VXD2142-03
VXD2142-04
VXD2152-06
VXD2262-10
VXD2272-32
VXD2382-40
VXD2392-50
1 to 99
Model
Model
E, P
Passage symbol
Passage symbol
differential (MPa)
differential (MPa)
Min. operating
Min. operating
temperature
pressure
pressure
–10 to 60
–10 to 40
0.02
0.03
0.02
0.03
Ambient
(°C)
2
1
2
1
Max. operating pressure
Max. operating pressure
0.7
1.0
0.7
1.0
AC
differential (MPa)
differential (MPa)
Tightness of Valve (Leakage Rate)
AC, DC
NBR, FKM, EPDM
0.7
Seal material
0.5
1.0
0.5
1.0
DC
Av x 10 -
Av x 10 -
Flow characteristics
Flow characteristics
1200
1200
0.2 cm
110
130
230
310
550
740
110
130
230
310
550
740
46
58
58
6
6
m
m
Leakage rate (With water pressure)
2
2
1 4
3
/min or less
to 1
Cv converted
Cv converted
13
23
31
49
13
23
31
49
1.9
2.4
4.5
2.4
5.5
9.5
4.5
5.5
9.5
Max. system
Max. system
1 cm
pressure
pressure
(MPa)
(MPa)
1.5
1.5
32A to 50A
3
/min or less
Weight
Weight
1150
1650
5400
6800
8400
1170
1690
5400
6800
8400
(g)
(g)
420
670
500
670
690
Note)
Note)

Related parts for VXD2140-04T-3CR1