VXD2140-04T-3CR1 SMC Corporation, VXD2140-04T-3CR1 Datasheet - Page 6

no-image

VXD2140-04T-3CR1

Manufacturer Part Number
VXD2140-04T-3CR1
Description
Process Solenoid Valve, 2 port, pilot operated, 1/2 port, NC, 110VAC, conduit
Manufacturer
SMC Corporation
Type
Pilot Operatedr
Datasheet

Specifications of VXD2140-04T-3CR1

Brand/series
VX Series
Number Of Ports
2
Primary Type
Solenoid Valve
Size, Port
1⁄2" NPTF
Voltage, Coil
110 VAC
Enclosure
Equivalent to IP65
Solenoid Valves Flow Characteristics
(4) Test method
By attaching the equipment for testing with the test circuit shown in Fig. (3) and running water at 5 to 40°C, measure the flow rate
with a pressure difference of 0.075 MPa. However, the pressure difference needs to be set with a large enough difference so that
4
the Reynolds number does not go below a range of 4 x 10
.
Av
By substituting the measurement results for formula (8) to figure out
.
Test range
Thermometer
Equipment for test
Pressure tap
Pressure tap
Flow meter
Throttle valve in the
Throttle valve in the
upstream side
downstream side
d
d
2
6
d
d
≥ 20
≥ 10
Fig. (3) Test circuit based on IEC60534-2-3, JIS B 2005
Front matter 6