E3X-NM11 Omron Automation, E3X-NM11 Datasheet
E3X-NM11
Specifications of E3X-NM11
Available stocks
Related parts for E3X-NM11
E3X-NM11 Summary of contents
Page 1
... J FIBER-OPTIC CABLES Please see the E32 Fiber-Optic Cables section. J ACCESSORIES Description Replacement protective cover for E3X-NTjj Replacement protective cover for E3X-NMjj Single channel None Provided None Provided E3X-NT11 E3X-NT21 E3X-NT41 E3X-NT51 2 E3X-N Four channel Provided Provided E3X-NM11 E3X-NM41 Part number E39-G8 E39-G9 ...
Page 2
... IP 50 (with cover on) — — Operating: --25°C to 55°C (--13°F to 131°F) with no ice buildup Storage: --40°C to 70°C (--40°F to 158°F) 3 E3X-N Four-channel E3X-NM11 E3X-NM41 150 mA max. 7 conductor cable, 7 conductor cable (6.5 ft) ...
Page 3
... Fiber Units to more than one E3X-NT (one channel), perform with/without-object teaching, in which case teach- ing must be performed on a single E3X- time. Therefore, turn on only the E3X-NT on which teaching is performed. If all the E3X-NTs are turned on, interrupt the emitters of the Fiber Units on which teaching is not performed. E3X-NM11 (NPN) E3X-NM41 (PNP) Four operation ...
Page 4
... E3X-N J MAXIMUM SENSITIVITY SETTING Note: The sensitivity of the E3X-NT and E3X-NM are set to maximum before shipping. When resetting the sensitivity of the E3X-NT or E3X-NM to maximum after no-object teaching or with/without-object teaching, follow the steps described below. Procedure Operation 1 Locate the sensor head within the rated sensing range with the E3X-Nj. ...
Page 5
... Select the logical output required with the operation mode selector. Note: 1. Even if the E3X-Nj is turned off, the E3X-Nj will retain the sensitivity set at the time of teaching. 2. Channels (E3X-NM) are selected in the following order. When all the channels are selected possible to set the sensitivity of the E3X-NM on all channels. ...
Page 6
... If the set distance is very short (i.e for the E32-TC200 and for the E32-DC200), no-object teaching is not possible due to excessive light, in which case, perform with/without-object teaching the teaching button is pressed for more than three seconds, the sensitivity of the E3X-Nj will be set to maximum, at which time the green indicator will be lit. ...