E3X-NM11 Omron Automation, E3X-NM11 Datasheet

no-image

E3X-NM11

Manufacturer Part Number
E3X-NM11
Description
Sensor, Fiber-Optic; NPN; 12 to 24 VDC + 10% @ 10% Ripple (Max.); 150 mA (Max.)
Manufacturer
Omron Automation
Type
Fiber Opticr
Datasheet

Specifications of E3X-NM11

Case Material
PBT Plastic
Cover Material
Polycarbonate
Current, Consumption
150 mA (Max.)
Function
Fiber Optic
Mounting Type
Bracket/DIN Rail
Output
NPN
Primary Type
Photoelectric
Response Time
500 μs (Max.) @ Rated detection distance
Technology
Photoelectric
Temperature, Ambient
-25 to +55 °C (Operating)
Temperature, Storage
-40 to +70 ºC
Voltage, Supply
12-24 VDC
Control Output
NPN Open Collector
Enclosure Rating
IP50
Lead Free Status / Rohs Status
RoHS Compliant part

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NM11
Manufacturer:
OMRON
Quantity:
475
High Performance DC Amplifier with
Pushbutton Sensitivity Adjustment
H
H
H
H
H
H
Ordering Information
J AMPLIFIERS
J FIBER-OPTIC CABLES
Please see the E32 Fiber-Optic Cables section.
J ACCESSORIES
Type
Off-delay timer
Remote teach input
Part number
Description
Replacement protective cover for E3X-NTjj
Replacement protective cover for E3X-NMjj
Auto-Tuning Fiber-Optic Sensor
Maintenance is made easier with
pushbutton sensitivity adjustment
Sensing distance is up to 100% longer
than standard amplifiers
Choose either single channel or four
channel models
Compact housing: 32 mm and 10 mm
housing widths
Four amplifiers in a single housing
saves space and wiring
Four fiber-optic cables can be mounted
directly next to each other without
mutual interference
NPN output
PNP output
R
Single channel
None
None
E3X-NT11
E3X-NT41
2
Provided
Provided
E3X-NT21
E3X-NT51
E3X-N
Four channel
Provided
Provided
E3X-NM11
E3X-NM41
Part number
E39-G8
E39-G9

Related parts for E3X-NM11

E3X-NM11 Summary of contents

Page 1

... J FIBER-OPTIC CABLES Please see the E32 Fiber-Optic Cables section. J ACCESSORIES Description Replacement protective cover for E3X-NTjj Replacement protective cover for E3X-NMjj Single channel None Provided None Provided E3X-NT11 E3X-NT21 E3X-NT41 E3X-NT51 2 E3X-N Four channel Provided Provided E3X-NM11 E3X-NM41 Part number E39-G8 E39-G9 ...

Page 2

... IP 50 (with cover on) — — Operating: --25°C to 55°C (--13°F to 131°F) with no ice buildup Storage: --40°C to 70°C (--40°F to 158°F) 3 E3X-N Four-channel E3X-NM11 E3X-NM41 150 mA max. 7 conductor cable, 7 conductor cable (6.5 ft) ...

Page 3

... Fiber Units to more than one E3X-NT (one channel), perform with/without-object teaching, in which case teach- ing must be performed on a single E3X- time. Therefore, turn on only the E3X-NT on which teaching is performed. If all the E3X-NTs are turned on, interrupt the emitters of the Fiber Units on which teaching is not performed. E3X-NM11 (NPN) E3X-NM41 (PNP) Four operation ...

Page 4

... E3X-N J MAXIMUM SENSITIVITY SETTING Note: The sensitivity of the E3X-NT and E3X-NM are set to maximum before shipping. When resetting the sensitivity of the E3X-NT or E3X-NM to maximum after no-object teaching or with/without-object teaching, follow the steps described below. Procedure Operation 1 Locate the sensor head within the rated sensing range with the E3X-Nj. ...

Page 5

... Select the logical output required with the operation mode selector. Note: 1. Even if the E3X-Nj is turned off, the E3X-Nj will retain the sensitivity set at the time of teaching. 2. Channels (E3X-NM) are selected in the following order. When all the channels are selected possible to set the sensitivity of the E3X-NM on all channels. ...

Page 6

... If the set distance is very short (i.e for the E32-TC200 and for the E32-DC200), no-object teaching is not possible due to excessive light, in which case, perform with/without-object teaching the teaching button is pressed for more than three seconds, the sensitivity of the E3X-Nj will be set to maximum, at which time the green indicator will be lit. ...