AD7151BRMZ Analog Devices Inc, AD7151BRMZ Datasheet - Page 15

IC CAP CONV 1CH ULT LP 10MSOP

AD7151BRMZ

Manufacturer Part Number
AD7151BRMZ
Description
IC CAP CONV 1CH ULT LP 10MSOP
Manufacturer
Analog Devices Inc
Type
Capacitance-to-Digital Converterr
Datasheet

Specifications of AD7151BRMZ

Input Type
Voltage
Output Type
Digital
Interface
2-Wire Serial
Current - Supply
120µA
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Resolution (bits)
12bit
Sampling Rate
100SPS
Input Channel Type
Single Ended
Data Interface
2-Wire, I2C, Serial
Supply Voltage Range - Analog
2.7V To 3.6V
Supply Current
70µA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7151BRMZ
Manufacturer:
EPOCS
Quantity:
30 000
Part Number:
AD7151BRMZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7151BRMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7151BRMZ-REEL
Manufacturer:
ADI
Quantity:
1 000
STATUS REGISTER
Address Pointer 0x00
8 Bits, Read-Only, Default Value 0x53 Before Conversion, 0x52 After Conversion
The status register indicates the status of the part. The register can be read via the 2-wire serial interface to query the status of the outputs,
check the CDC finished conversion, and check whether the CAPDAC has been changed by the autoCAPDAC function.
Table 6. Status Register Bit Map
Bit
Mnemonic
Default
Table 7. Status Register Bit Descriptions
Bit
7
6
5
4
3
2
1
0
Mnemonic
PwrDown
DacStep
OUT
RDY
Description
PwrDown = 1 indicates that the part is in a power-down mode or that the part V
monitor threshold voltage.
Bit not used, always reads 1.
Bit not used, always reads 0.
DacStep = 0 indicates that the CAPDAC value was changed during the last conversion as part of the AutoDac
function. The bit value is updated after each finished CDC conversion.
OUT = 1 indicates that the data (CIN capacitance) crossed the threshold, according to the selected comparator
mode of operation. The bit value is updated after each finished CDC conversion.
Bit not used, always reads 0.
Bit not used, always reads 1.
RDY = 0 indicates a finished CDC conversion. The bit is reset back to 1 when the data register is read via the
serial interface or after the part reset or power-up.
PwrDown
Bit 7
0
Bit 6
1
Bit 5
Rev. 0 | Page 15 of 28
0
DacStep
Bit 4
1
Bit 3
OUT
0
Bit 2
0
DD
is below the power supply
Bit 1
1
AD7151
Bit 0
RDY
1

Related parts for AD7151BRMZ