AD7151BRMZ Analog Devices Inc, AD7151BRMZ Datasheet - Page 22

IC CAP CONV 1CH ULT LP 10MSOP

AD7151BRMZ

Manufacturer Part Number
AD7151BRMZ
Description
IC CAP CONV 1CH ULT LP 10MSOP
Manufacturer
Analog Devices Inc
Type
Capacitance-to-Digital Converterr
Datasheet

Specifications of AD7151BRMZ

Input Type
Voltage
Output Type
Digital
Interface
2-Wire Serial
Current - Supply
120µA
Mounting Type
Surface Mount
Package / Case
10-MSOP, Micro10™, 10-uMAX, 10-uSOP
Resolution (bits)
12bit
Sampling Rate
100SPS
Input Channel Type
Single Ended
Data Interface
2-Wire, I2C, Serial
Supply Voltage Range - Analog
2.7V To 3.6V
Supply Current
70µA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7151BRMZ
Manufacturer:
EPOCS
Quantity:
30 000
Part Number:
AD7151BRMZ
Manufacturer:
ADI
Quantity:
1 000
Part Number:
AD7151BRMZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7151BRMZ-REEL
Manufacturer:
ADI
Quantity:
1 000
AD7151
If a repeated start condition is encountered after the address
pointer byte, all peripherals connected to the bus respond
exactly as outlined previously for a start condition; that is, a
repeated start condition is treated the same as a start condition.
When a master device issues a stop condition, it relinquishes
control of the bus, allowing another master device to take
control of the bus. Therefore, a master wanting to retain control
of the bus issues successive start conditions known as repeated
start conditions.
AD7151 RESET
To reset the AD7151 without having to reset the entire serial bus,
an explicit reset command is provided. This uses a particular
address pointer word as a command word to reset the part and
upload all default settings. The AD7151 does not respond to the
serial bus commands (do not acknowledge) during the default
values upload for approximately 2 ms.
The reset command address word is 0xBF.
SEQUENCE
SEQUENCE
WRITE
READ
S SLAVE ADDR A(S)
S SLAVE ADDR A(S)
S = START BIT
P = STOP BIT
SCLOCK
SDATA
LSB = 0
START ADDR R/W ACK SUBADDRESS ACK
A(S) = ACKNOWLEDGE BY SLAVE
A(M) = ACKNOWLEDGE BY MASTER
S
SUB ADDR
SUB ADDR
1–7
Figure 41. Write and Read Sequences
8
A(S)
A(S) S SLAVE ADDR
Figure 40. Bus Data Transfer
9
Rev. 0 | Page 22 of 28
DATA
1–7
LSB = 1
8
A(S)
A(S) = NO ACKNOWLEDGE BY SLAVE
A(M) = NO ACKNOWLEDGE BY MASTER
GENERAL CALL
When a master issues a slave address consisting of seven 0s with
the eighth bit (R/W bit) set to 0, this is known as the general call
address. The general call address is for addressing every device
connected to the serial bus. The AD7151 acknowledges this
address and reads in the following data byte.
If the second byte is 0x06, the AD7151 is reset, completely
uploading all default values. The AD7151 does not respond to
the serial bus commands (do not acknowledge) during the
default values upload for approximately 2 ms.
The AD7151 does not acknowledge any other general call
commands.
9
A(S)
1–7
DATA
DATA
8
DATA
ACK
A(M)
9
STOP
P
A(S)
P
DATA
A(M)
P

Related parts for AD7151BRMZ