KSZ8041TL A3 Micrel Inc, KSZ8041TL A3 Datasheet - Page 46

no-image

KSZ8041TL A3

Manufacturer Part Number
KSZ8041TL A3
Description
Manufacturer
Micrel Inc
Datasheet

Specifications of KSZ8041TL A3

Lead Free Status / Rohs Status
Supplier Unconfirmed
Micrel, Inc.
December 2009
Address
1e.12
1e.11
1e.10:8
1e.7
1e.6:0
Register 1Fh – PHY Control 2
1f.15
1f.14
1f.13
1f.12
1f.11
1f.10
1f.9
1f.8
1f.7
1f.6
Name
Far-End Fault
Detect
MDI/MDI-X
State
Reserved
Remote
loopback
Reserved
HP_MDIX
MDI/MDI-X
Select
Pairswap
Disable
Energy Detect
Force Link
Power Saving
Interrupt Level
Enable Jabber
Auto-
Negotiation
Complete
Enable Pause
(Flow Control)
Description
0 = Far-End Fault not detected
1 = Far-End Fault detected
This bit applies to KSZ8041FTL fiber only.
0 = MDI
1 = MDI-X
0 = Normal mode
1 = Remote (analog) loop back is enable
0 = Micrel Auto MDI/MDI-X mode
1 = HP Auto MDI/MDI-X mode
When Auto MDI/MDI-X is disabled,
0 = MDI Mode
1 = MDI-X Mode
1 = Disable auto MDI/MDI-X
0 = Enable auto MDI/MDI-X
1 = Presence of signal on RX+/- analog wire
0 = No signal detected on RX+/-
1 = Force link pass
0 = Normal link operation
This bit bypasses the control logic and allow
transmitter to send pattern even if there is no
link.
1 = Enable power saving
0 = Disable power saving
If power saving mode is enabled and the cable
is disconnected, the RXC clock output (in MII
mode) is disabled. RXC clock is enabled after
the cable is connected and link is established.
1 = Interrupt pin active high
0 = Interrupt pin active low
1 = Enable jabber counter
0 = Disable jabber counter
1 = Auto-negotiation process completed
0 = Auto-negotiation process not completed
1 = Flow control capable
0 = No flow control capability
Transmit on RX+/- (pins 10,9) and
Receive on TX+/- (pins 12,11)
pair
Transmit on TX+/- (pins 12,11) and
Receive on RX+/- (pins 10,9)
46
Mode
RO
RO
RW
RW
RW
RW
RO
RW
RW
RW
RW
RO
RO
(1)
Default
0
0
1
0
0
0
0
0
0
1
0
0
KSZ8041TL/FTL/MLL