XE056LCC-2 Cermetek Microelectronics, XE056LCC-2 Datasheet

no-image

XE056LCC-2

Manufacturer Part Number
XE056LCC-2
Description
Manufacturer
Cermetek Microelectronics
Datasheet

Specifications of XE056LCC-2

Lead Free Status / Rohs Status
Supplier Unconfirmed
Description
The XE056LCC is a complete telephone line
interface or DAA supporting 56K bps data transfer
in a leadless, surface-mount package. It is an
alternative to discrete DAA’s for high-speed dial-
up communications. The XE056LCC replaces 25
to 30 discrete components.
In spite of being less than 1 inch square, the
XE056LCC does not sacrifice performance for its
small size and surface-mount convenience. The
wide bandwidth, low distortion design supports
data transfer with even V.90 and V.92 modulation.
The XE056LCC includes the telephone line
transformer, loop current holding circuit, hook-
switch and ring indicator. The XE056LCC
complies with FCC Part 68 rules for direct
connection to the telephone line.
Cermetek
Surface-Mount Slim-Link
XE056LCC BLOCK DIAGRAM
®
DAA for 56K bps Data Transfer
(1)
Models
XE056LCC1 - open PCB
XE056LCC2 - shielded module
Features
* Leadless design compatible with a 68-Pin
* Meets line interface requirements for reliable
* Typical Total Harmonic Distortion -77 dB ;
* FCC Part 68 Compliant;
* Integrated Low-Distortion Telephone Line
* Ring Detection;
* Operates on a Single +5 Volt or + 3 Volt
* Solid-State Hook-switch Control;
* Internal metallic surge protection provided;
* Extended Temperature Ranges available;
PLCC footprint for high-volume assembly
voice, audio and data communications;
Transformer
Power Supply;
XE056LCC
XE056LCC
January 2009

Related parts for XE056LCC-2

XE056LCC-2 Summary of contents

Page 1

... DAA’s for high-speed dial- up communications. The XE056LCC replaces discrete components. In spite of being less than 1 inch square, the XE056LCC does not sacrifice performance for its small size and surface-mount convenience. The wide bandwidth, low distortion design supports data transfer with even V.90 and V.92 modulation. ...

Page 2

... XE056LCC2 Mechanical Specifications Cermetek Inches MM Dim Min Max Min A 0.950 0.960 24.13 24.38 B 0.950 0.960 24.13 24.38 C 0.345 0.355 8.76 D 0.095 0.105 2.41 E 0.795 0.805 20.19 20.45 F 0.070 0.080 1.90 G 0.040 0.050 1.02 H 0.055 0.065 1.40 (2) Max 9.02 2.67 2.03 1.27 1 ...

Page 3

... XE056LCC PCB Layout Recommendations The XE056LCC is a leadless part. The pads on your printed circuit board must align with the pads on the bottom of the DAA mdule. Below is the recommended PCB layout. Do not place trace or components under the DAA as this could compromise the network isolation. ...

Page 4

... Ground connection to the XE056LCC. Pin 10 supplies the reference for the RI input and /OH output and should connect to the systems digital ground. 11 VCC + Volt power source for the XE056LCC. VCC powers the RI and OH control lines. 12 /OH Active low Switch-hook control. A low on /OH closes the switch-hook causing the DAA to seize the local telephone line ...

Page 5

... FCC Part 68 Rules. FB1., FB2 FB1 and FB2 are ferrite beads provided for EMI filtering. Xecom recommends the TDK ACB2012L-120 which provides more than 100 ohms impedance above 100 MHz. Cermetek (5) XE056LCC ...

Page 6

... Slim-Link PLCC Soldering Instructions Because of its Hybrid construction, the XE056LCC DAA is subject to damage if over exposed to heat during solder reflow operations. Following the soldering instructions below will ensure that the process of soldering the module to the board does not damage the DAA. ...

Page 7

... Insertion Loss: There is some loss of signal strength as the signal passes through the DAA. This "insertion" loss should be considered when placing signals across T1 and T2 for transmission. The typical insertion loss of the XE056LCC is 6 dB. Total Harmonic Distortion: Total harmonic distortion measures the quality of the DAA signal path quality ...

Page 8

... The 2/4 wire convertor separates these signals at the host interface. Most modem analog front end chips incorporate an internal 2/4 wire convertor. If you are using the XE056LCC for an application other than a modem, such as audio, or your modem analog front end does not provide the 2/4 wire convertor, you will need to provide a discrete 2/4 wire convertor ...

Page 9

... Hook-Switch Control Voltage (active low) Hook-Switch Control Current Loop Current DC On-Hook Impedance XE056LCC Absolute Maximum Ratings Operating Temperature Range * * The XE056LCC can be ordered with an Operating Temperature of -40 Order Model Number XE056LCC-ITR Cermetek (Vcc=+5v ±10%, Ta deg C) Conditions Off-hook On-hook 600 Ohm Impedance, 1800 Hz ...

Page 10

... Billing Delay A delay of 2 seconds or greater is required after the time the XE056LCC is taken “off hook” and before any information is transmitted. This is required to ensure that billing information may be exchanged between telephone company central offices without interference. ...

Page 11

... Product mentioned herein are used for identification purposes only and may be trademarks and/or registered trademarks of their respective companies. Cermetek Cermetek Microelectronics, Inc 374 Turquoise Street, Milpitas, CA 95035 Ph:408-942-2200 Fax:408-942-1346 Email: info@cermetek.com Web Site: http://www.cermetek.com (11) XE056LCC ...