DSPD56367AG150 Freescale Semiconductor, DSPD56367AG150 Datasheet - Page 33

no-image

DSPD56367AG150

Manufacturer Part Number
DSPD56367AG150
Description
DSP Fixed-Point 24-Bit 150MHz 150MIPS 144-Pin LQFP Tray
Manufacturer
Freescale Semiconductor
Datasheet

Specifications of DSPD56367AG150

Package
144LQFP
Numeric And Arithmetic Format
Fixed-Point
Maximum Speed
150 MHz
Ram Size
69 KB
Device Million Instructions Per Second
150 MIPS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSPD56367AG150
Manufacturer:
FREESCALE/PB-FREE
Quantity:
126
Freescale Semiconductor
1
2
3
4
5
6
7
8
No.
28
29
V
Periodically sampled and not 100% tested.
RESET duration is measured during the time in which RESET is asserted, V
valid. When the V
the device circuitry will not be in an initialized state that can result in significant power consumption and heat-up. Designs
should minimize this state to the shortest possible duration.
If PLL does not lose lock.
When using fast interrupts and IRQA, IRQB, IRQC, and IRQD are defined as level-sensitive, timings 19 through 21 apply to
prevent multiple interrupt service. To avoid these timing restrictions, the deasserted Edge-triggered mode is recommended
when using fast interrupts. Long interrupts are recommended when using Level-sensitive mode.
WS = number of wait states (measured in clock cycles, number of T
Use expression to compute maximum value.
This timing depends on several settings:
For PLL disable, using external clock (PCTL Bit 16 = 1), no stabilization delay is required and recovery time will be defined
by the PCTL Bit 17 and OMR Bit 6 settings.
For PLL enable, if PCTL Bit 17 is 0, the PLL is shutdown during Stop. Recovering from Stop requires the PLL to get locked.
The PLL lock procedure duration, PLL Lock Cycles (PLC), may be in the range of 0 to 1000 cycles. This procedure occurs
in parallel with the stop delay counter, and stop recovery will end when the last of these two events occurs: the stop delay
counter completes count or PLL lock procedure completion.
PLC value for PLL disable is 0.
The maximum value for ET
4096/150 MHz = 27.3 µs). During the stabilization period, T
timing may vary as well.
CCQH
DMA Requests Rate
Delay from IRQA, IRQB, IRQC, IRQD, NMI assertion to
external memory (DMA source) access address out valid
• Data read from HDI08, ESAI, ESAI_1, SHI, DAX
• Data write to HDI08, ESAI, ESAI_1, SHI, DAX
• Timer
• IRQ, NMI (edge trigger)
= 3.3 V ± 5%; V
CC
Table 3-7 Reset, Stop, Mode Select, and Interrupt Timing
is valid, but the other “required RESET duration” conditions (as specified above) have not been yet met,
CC
= 1.8V ± 5%; T
C
Characteristics
is 4096 (maximum MF) divided by the desired internal frequency (i.e., for 150 MHz it is
J
DSP56367 Technical Data, Rev. 2.1
= –40°C to + 95°C, C
C
, T
H
L
, and T
= 50 pF
C
).
L
will not be constant, and their width may vary, so
Reset, Stop, Mode Select, and Interrupt Timing
4.25 × T
Expression
CC
6T
7T
2T
3T
is valid, and the EXTAL input is active and
C
C
C
C
C
+ 2.0
1
(continued)
30.3
Min
Max
40.0
46.7
13.3
20.0
Unit
ns
ns
3-9

Related parts for DSPD56367AG150