XPSDME1132P Crouzet USA, XPSDME1132P Datasheet - Page 118

89H6665

XPSDME1132P

Manufacturer Part Number
XPSDME1132P
Description
89H6665
Manufacturer
Crouzet USA
Datasheet

Specifications of XPSDME1132P

Contact Current Max
8mA
Contact Voltage Dc Nom
24V
Contact Configuration
DPST-NO
Relay Mounting
DIN Rail
External Height
66mm
External Width
114mm
External Depth
45mm
Rohs Compliant
Yes
Wiring diagrams
Configuration 14 (automatic or unmonitored start, synchronization time = 1.5 s) = function 1.
Configuration 15 (monitored start, synchronization time = 1.5 s) = function 2.
(1) Automatic start.
(2) Function 1 safety outputs.
Configuration 14
Automatic start
Key
Input 1
C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Automatic start C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
Configuration 15
Monitored start
Key
Input 1 C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Start button C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
XPSMP
Non-contact safety interlock switch monitoring
+
0 V
Functional diagrams
24 V
F1
0
0
A2
A1
C3
C6
1
1
C2
I4
Non-contact safety interlock switch
not activated F1
Non-contact safety interlock switch
not activated F2
Power-up (Self-test accomplished)
Power-up (Self-test accomplished)
Actuator part
present
Actuator part
present
C1
t < 10 s
S12
Logic
channel 1
Logic
channel 2
S45
C4
(continued)
I1
Actuator part
absent
Actuator part
absent
t < 1,5 s
C5
I2
XCS DM
XCS DM
Function 1
Function 2
Function 1
Function 2
Actuator part
present
t < 1,5 s
Actuator part
present
(F1)
(F2)
(F1)
(F2)
Start F2
I5
Start F1
ESC
ESC
t < 10 s
F2
Safety automation system solutions
Preventa™ safety controllers type XPSMP
With pre-defined functions
K21
K22
F1
K3
K4
K11
K12
K1
K2
I6
I3
S6
S3
Function 1
(1)
K11
13
14
(3) Function 2 safety outputs.
ESC = External start conditions.
Configuration 14
Unmonitored start
Input 1
C1-I1, (C4-I4)
Input 2 C2-I2, (C5-I5)
Start button C3-I3,
(C6-I6)
N.O. output 13-14/23-24/
33-34, (43-44/53-54/63-64)
Signalling output Y84,
(Y94)
Key
Function 1
24
23
K12
(2)
0
33
34
Function 2
1
K21
43
44
Power-up (Self-test accomplished)
Actuator part
present
Function 2
53
54
K22
(3)
63
64
Actuator part
absent
Y
+
Y74
XPS MP
Y84
Actuator part
present
t < 1,5 s
Y94
To PLC
2/117
10
10
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9

Related parts for XPSDME1132P