BTS 5562E Infineon Technologies, BTS 5562E Datasheet - Page 28

no-image

BTS 5562E

Manufacturer Part Number
BTS 5562E
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS 5562E

Packages
PG-DSO-36
Channels
5.0
Channel Mix
3x50mohm+2*130mohm
Led Mode
No
Cranking Mode
No
Pwm Engine Integrated
No
For diagnosis feedback at different operation modes, please see
Table 1
Operation Mode
Normal Operation (OFF)
Short Circuit to GND
Thermal shut down
Short Circuit to
Open Load
Normal Operation (ON)
Current Limitation
Short Circuit to GND
Dynamic Temperature Sensor shut down
Thermal shut down
Short Circuit to
Open Load
1) L = low level, H = high level, Z = high impedance, potential depends on leakage currents and external circuit.
2) The error flags are latched until they are transmitted in the standard diagnosis word via SPI.
3) The over temperature flag is set latched (in OFF states also) and can be cleared by SPI command HWCR.CTL.
8.1
The standard diagnosis at the SPI interface provides information about each channel. The error flags, an OR
combination of the over temperature flags and the over load monitoring signals are provided in the SPI standard
diagnosis bits ERRn.
The over load monitoring signals are latched in the error flags and cleared each time the standard diagnosis is
transmitted via SPI. In detail, they are cleared between the second and third raising edge of the SCLK signal.
The over temperature flags, which cause an overheated channel to latch off, are latched directly at the gate control
block. The latches are cleared by SPI command HWCR.CTL.
Please note: The over temperature information is latched twice. When transmitting a clear thermal latch command
(HWCR.CTL), the error flag is cleared during command transmission of the next SPI frame and ready for latching
after the third raising edge of the SCLK signal. As a result, the first standard diagnosis information after a CTL
command will indicate a failure mode at the previously affected channels although the thermal latches have been
cleared already. In case of continuous over load, the error flags are set again immediately because of the over
load monitoring signal.
Data Sheet
x = undefined.
Operation Modes
Diagnosis Word at SPI
V
V
BB
BB
1)
Input Level
OUT.OUTn
L / 0
(OFF-state)
H / 1
(ON-state)
28
Output
Level V
GND
GND
Z
V
Z
~
<
~GND
Z
Z
V
V
V
BB
BB
BB
V
BB
Table
BB
OUT
1.
Current
Sense I
Z
Z
Z
Z
Z
I
Z
Z
Z
Z
< I
Z
L
/ k
L
/ k
ILIS
ILIS
IS
Error Flag
ERRn
0
0
0
0
0
0
1
1
1
1
0
0
SPOC - BTS5562E
3)
3)
Rev. 1.0, 2008-05-15
2)
Diagnosis
DCR.
SBM
1
1
x
0
x
0
x
1
x
x
0
0