BTS5030-1EJA Infineon Technologies, BTS5030-1EJA Datasheet - Page 31

no-image

BTS5030-1EJA

Manufacturer Part Number
BTS5030-1EJA
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS5030-1EJA

Packages
PG-DSO-8
Channels
1.0
Ron @ Tj = 25°c
30.0 mOhm
Recommended Operating Voltage Min.
5.0 V
Recommended Operating Voltage Max.
28.0 V
Il(sc)
36.0 A

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS5030-1EJA
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS5030-1EJA
Quantity:
760
Part Number:
BTS5030-1EJA
0
Company:
Part Number:
BTS5030-1EJA
Quantity:
4 800
7.3.3
7.3.3.1
If the channel is ON, a leakage current can still flow through an open load, for example due to humidity. The
parameter
DMOS is below this value, the device recognizes a failure, if the DEN is selected. In that case, the SENSE current
is below
SENSE current behavior in this area. The red curve shows a typical product curve. The blue curve shows the ideal
k
Figure 24
7.3.3.2
For open load diagnosis in OFF-state, an external output pull-up resistor (
calculation of pull-up resistor value, the leakage currents and the open load threshold voltage
taken into account.
system, including
application.
To reduce the stand-by current of the system, an open load resistor switch S
OFF, the output is no longer pulled down by the load and
the device as an open load. The voltage threshold is given by
to the
An additional
used as well for short circuit to battery detection, see
Data Sheet
PROFET™+ 12V
ILIS
ratio.
I
IS(FAULT)
I
IS(OL)
I
L(OL)
SENSE Signal in Open Load
Open Load in ON Diagnostic
Current Sense Ratio for Low Currents
Open Load in OFF Diagnostic
R
. Otherwise, the minimum SENSE current is given above parameter
.
PD
gives the threshold of recognition for this leakage current. If the current
resistor can be used to pull
I
L(OFF)
Figure 25
(see
I
IS(OL)
Chapter
gives a sketch of the situation.
I
IS
5.5) and external leakages, e.g, due to humidity, corrosion, etc.... in the
V
OUT
to 0V. Otherwise, the OUT pin is floating. This resistor can be
Chapter
31
V
I
L(OL)
OUT
V
I
7.3.4.
leakage
OL(OFF)
voltage rises to nearly
defines the leakage current in the complete
. In that case, the SENSE signal is switched
Sense for OL .vsd
OL
is recommended. If the channel is
R
I
OL
L
) is recommended. For the
I
IS(OL)
V
I
S
L
Diagnostic Functions
. This is recognized by
.
flowing out the power
Rev. 2.1, 2011-06-20
Figure 24
BTS5030-1EJA
V
OL(OFF)
have to be
shows the

Related parts for BTS5030-1EJA