CMX228S1 MX-COM, Inc., CMX228S1 Datasheet - Page 19

no-image

CMX228S1

Manufacturer Part Number
CMX228S1
Description
ISDN data and telephony protocol engine with x.25
Manufacturer
MX-COM, Inc.
Datasheet
ISDN Data and Telephony Protocol Engine with x.25
4.6.2
In addition to the commands, there are a group of registers for which data is entered in the following format:
AT{register}={value}<CR>. The following Hayes registers are supported:
The following is a more detailed description of the Hayes registers listed above:
S0 (Rings on Which to Auto-answer a Data Call)
MX-COM, Inc
4800 Bethania Station Road, Winston-Salem, NC, 27105-1201, USA
www.mxcom.com tel: 800 638 5577 336 744 5050 fax: 336 744 5054
All trademarks and service marks are held by their respective companies
Hayes Register Set
Range
0 to 255
Default
S0
S37
%A2
%B0
%B1
%B2
%B3
%B13
%B18
%D0
%D1
%D2
%D3
%D9
%D10
%E8
%L3
%L4
%L10
!B1
!B2
!B3
!B5
!C4
!C5
!C6
!C7
!C8
0
- Number of rings on which to auto- answer
- Maximum rate adaption speed
- B/D - channel protocol
- X.25 receive window size
- X.25 transmit window size
- X.25 receive packet size
- X.25 transmit packet size
- X.25 NUI
- X.25 user data
- X.25 default receive window size
- X.25 default transmit window size
- X.25 default receive packet size
- X.25 default transmit packet size
- X.25 group number
- X.25 channel number
- V.120 MFO mode selection
- PAD forwarding character
- PAD idle timer
- PAD line folding
- LAPB T1 timer
- LAPB T4 timer
- LAPB N2 retry count
- X.25 LAPB active/passive
- B1 - channel configuration
- B2 - channel configuration
- Multiple Subscriber Numbering
- TEI selection
- ISDN Line Failure Detection enable/disable
Description
If set to 0 auto-answering will be disabled.
Any other value will cause one ‘RING’ result code to
be sent to the DTE after which the call is answered.
19
2000 Chiron Technology Limited
CMX228 Advance Information
Doc. # 20480216.001
2000 MX-COM, Inc.

Related parts for CMX228S1