If the mere presence of some voltage potential is adequate
prior to sequencing on, then a small number of standard
logic AND gates can be used to accomplish this. The block
diagram in Figure 18 illustrates this voltage presence
configuration.
In either case, the sequencing is straight forward across
multiple sequencers as all DLY_ON capacitors will
simultaneously start charging ~10ms after the common
ENABLE input signal is delivered. This allows the choice of
capacitors to be related to each other no different than using
a single sequencer. When the common enabling signal is
deasserted these configurations will then execute the
turn-off sequence across all sequencers as programmed by
the DLY_OFF capacitor values.
In both cases, with all the SYSRST# pins bussed together,
once the on sequence is complete, simultaneous shutdown
upon any UVLO input failure is assured as SYSRST# output
will momentarily pull low turning off all GATE and LOGIC
outputs.
There may be applications that require or allow groups of
supplies being brought up in sequence and supplies within
each group to be sequenced. Figure 19 illustrates such a
configuration that allows the first group of supplies to turn-on
before the second group starts. This arrangement does not
necessarily preclude adding the assurance of all supplies
prior to turn-on sequencing as previously shown but it will
RESET#
en
SUPPLY
POWER
FIGURE 17. ISL612X AND ISL613X VOLTAGE COMPLIANT
PGOOD
ON ALL RAILS
MONITORING
ISL613Xs
SEQUENCING BLOCK DIAGRAM
VMON
ISL6123, ISL6124, ISL6125, ISL6126, ISL6127, ISL6128, ISL6130
17
UVLO
SYSRST#
RESET#
RESET#
UVLO
SYSRST#
ISL6125
ISL6124
# N
ENABLE#
ENABLE#
# N+1
L
O
G
I
C
G
A
T
E
OE
LOW = RESET
prevent the turn-on sequence from completing if there is one
unsatisfied UVLO input in a group. Using this configuration
involves waiting through the T
~160ms) for each sequencer IC in the chain for the final
RESET# to release. Once ENABLE on the first sequencer is
deasserted all the RESET# outputs will quickly pull low and
thus allow the sequenced turn-off of this configuration to
ripple through several banks as quickly as the user
programmed sequence as chosen by the DLY_OFF
capacitors allow. Once again with common bussed
SYSRTS# pins, simultaneous shut down of all GATEs and
LOGIC down upon an unsatisfied UVLO input is assured
once all FETs or LOGIC output are on. If a GATE drive
option IC is used to drive both FETs and logic signals then
care to ensure the charged pump GATE does not over drive
and damage the logic input must be taken. A simple resistor
divider can be used to lower the GATE voltage to a suitable
voltage for the logic input as shown in Figure 19.
FIGURE 18. MULTIPLE ISL612X USING LOGIC GATES FOR
RESET#’
en
POWER
SUPPLY
VOLTAGE PRESENCE DETECT
UVLO
UVLOdel
UVLO
RESET#
SYSRST#
RESET#
UVLO
SYSRST#
ISL6125
ISL6124
# N
ENABLE#
ENABLE#
# N+1
and T
OE
L
O
G
I
C
G
A
T
E
RSTdel