TABLE 1. SOFTWARE COMMAND DEFINITIONS
Note:
1. ADI = Address of Device identifier;A1=0, A0 =0 for manufacture code, A1=0, A0 =1 for device code.(Refer to
2. PA = Address of memory location to be programmed.
3. The system should generate the following address patterns: 555H or 2AAH to Address A0~A10.
4. For chip protect verify operation : If read out data is 01H, it means the chip has been protected. If read out data
COMMAND DEFINITIONS
Device operations are selected by writing specific ad-
dress and data sequences into the command register.
Writing incorrect address and data values or writing
them in the improper sequence will reset the device to
the read mode. Table 1 defines the valid register
P/N: PM0515
Command
Reset
Read
Read Silicon ID
Chip Protect Verify
Program
Chip Erase
Sector Erase
Sector Erase Suspend 1
Sector Erase Resume
Unlock for chip
protect/unprotect
Table 3)
DDI = Data of Device identifier : C2H for manufacture code, 18H/19H for device code.
X = X can be VIL or VIH
RA=Address of memory location to be read.
RD=Data to be read at location RA.
PD = Data to be programmed at location PA.
SA = Address to the sector to be erased.
Address bit A11~A16=X=Don't care for all address commands except for Program Address (PA) and Sector
Address (SA). Write Sequence may be initiated with A11~A16 in either state.
is 00H, it means the chip is still not being protected.
Bus
Cycle Addr
1
1
4
4
4
6
6
1
6
XXXH
XXXH
XXXH
555H
555H
555H
555H
555H
555H
RD
First Bus
Cycle
Data
AAH
AAH
AAH
AAH
AAH
AAH
B0H
30H
F0H
RD
2AAH
2AAH
2AAH
2AAH
2AAH
2AAH
Addr
Second Bus
Cycle
Data
55H
55H
55H
55H
55H
55H
5
555H 90H
555H 90H
555H A0H
555H 80H
555H 80H
555H 80H
command sequences. Note that the Erase Suspend
(B0H) and Erase Resume (30H) commands are valid
only while the Sector Erase operation is in progress.
Either of the two reset command sequences will reset
the device(when applicable).
Addr Data
Third Bus
Cycle
X02H
555H
555H
555H
Addr
(SA)
ADI
PA
Fourth Bus
MX29F001T/B
Cycle
Data
AAH
AAH
AAH
00H
01H
DDI
PD
2AAH
2AAH
2AAH 55H
Fifth Bus
Addr Data
Cycle
55H
55H
REV. 2.5,NOV. 20, 2002
555H 20H
Addr Data
555H 10H
SA
Sixth Bus
Cycle
30H