Current Transducer LF 505-S
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
I
I
R
I
K
V
I
X
I
I
t
di/dt
f
T
T
R
m
Note :
060922/9
SN
OT
PN
P
C
O
r
A
S
C
L
M
N
G
S
Electrical data
Accuracy - Dynamic performance data
General data
Primary nominal rms current
Primary current, measuring range
Measuring resistance
Secondary nominal rms current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
Overall accuracy @ I
Linearity error
Offset current @ I
Thermal drift of I
Response time
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
Mass
Standards
1)
With a di/dt of 100 A/µs.
with ± 15 V
with ± 18 V
with ± 24 V
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
1)
O
@ 90 % of I
P
= 0, T
PN
, T
A
A
@ ± 500 A
@ ± 800 A
@ ± 500 A
@ ± 800 A
@ ± 500 A
@ ± 800 A
= 25°C
= 25°C
PN
- 40°C .. + 70°C
max
max
max
max
max
max
T
A
= 70°C
16137
500
0 .. ± 800
R
100
1 : 5000
± 15 .. 24
24
± 0.6
< 0.1
< 1
> 100
DC .. 100
- 40 .. + 70
- 40 .. + 85
70
230
EN 50155 : 1995
EN 50178 : 1997
± 0.1
0
0
0
0
5
5
Typ
M min
(@ ± 18 V) +
± 0.4
± 0.4
Max
149
R
60
11
92
30
65
M max
I
S
A/µs
kHz
mA
mA
mA
mA
°C
°C
µs
%
%
V
A
A
g
I
Features
Advantages
Applications
Applications domain
PN
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Traction
Industrial.
=
500 A
www.lem.com
page 1/3

Related parts for lf505-s06

lf505-s06 Summary of contents

Page 1

Current Transducer LF 505-S For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data I Primary nominal rms current PN I Primary ...

Page 2

LF 505-S Current Transducer Isolation characteristics V R.m.s. voltage for AC isolation test Impulse withstand voltage 1.2/50 µs w dCp Creepage distance dCl Clearance distance CTI Comparative Tracking Index (Group IIIa) Application examples According ...

Page 3

Dimensions LF 505-S (in mm 0.0394 inch) Bottom view Right view Top view Mechanical characteristics General tolerance ± 0.5 mm Transducer fastening Vertical or flat lying position holes steel screws M4 ...

Related keywords