lf505-s06 ETC-unknow, lf505-s06 Datasheet - Page 3

no-image

lf505-s06

Manufacturer Part Number
lf505-s06
Description
Current Transducer
Manufacturer
ETC-unknow
Datasheet
Dimensions LF 505-S
Mechanical characteristics
060922/9
Vertical or flat lying position
Bottom view
Right view
Top view
General tolerance
Transducer fastening
Recommended fastening torque
or vertical position
Recommended fastening torque
or flat lying position
Recommended fastening torque
Primary through-hole
Connection of secondary
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
(in mm. 1 mm = 0.0394 inch)
± 0.5 mm
4 or 6 holes
4 or 6 steel screws M4
3.2 Nm or 2.37 Lb.-Ft.
4 holes
depth : 7.5 mm
4 screws PTKA 25,
length: 6 mm
0.7 Nm or 0.52 Lb.-Ft.
4 holes
4 screws PTKA 25,
length:10 mm
0.75 Nm or 0.55 Lb.-Ft.
MOLEX 5045-03/A
30.2 mm
1.9 mm, crossing
1.9 mm,
4.3 mm
Remarks
I
Temperature of the primary conductor should not exceed
100°C.
Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...), please
contact us.
S
is positive when I
Connection
P
flows in the direction of the arrow.
Back view
www.lem.com
page 3/3