xr16v2651im Exar Corporation, xr16v2651im Datasheet - Page 16

no-image

xr16v2651im

Manufacturer Part Number
xr16v2651im
Description
High Performance Duart With 32-byte Fifo And Powersave
Manufacturer
Exar Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
xr16v2651im-F
Manufacturer:
Exar Corporation
Quantity:
10 000
XR16V2651
HIGH PERFORMANCE DUART WITH 32-BYTE FIFO AND POWERSAVE FEATURE
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control
features is enabled to fit specific application requirement (see
If using the Auto RTS interrupt:
F
2.12
IGURE
Enable auto RTS flow control using EFR bit-6.
The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
Enable RTS interrupt through IER bit-6 (after setting EFR bit-4). The UART issues an interrupt when the
RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
Receive Data
16X or 8X or 4X Clock
Byte and Errors
32 bytes by 11-bit wide
9. R
Auto RTS (Hardware) Flow Control
( DLD[5:4] )
ECEIVER
FIFO
O
PERATION IN
Receive Data Shift
Register (RSR)
Data FIFO
FIFO
Receive
Receive
Data
AND
A
UTO
Validation
Data falls to
Trigger=16
Data fills to
Data Bit
FIFO
24
RTS F
8
Example
16
: - RX FIFO trigger level selected at 16 bytes
LOW
RTS# re-asserts when data falls below the flow
control trigger level to restart remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
RTS# de-asserts when data fills above the flow
control trigger level to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
RHR Interrupt (ISR bit-2) programmed for
(See Note Below)
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
Figure
C
ONTROL
10):
M
ODE
Receive Data Characters
RXFIFO1
REV. 1.0.2

Related parts for xr16v2651im