ml7012-04 Oki Optical Components, ml7012-04 Datasheet - Page 13

no-image

ml7012-04

Manufacturer Part Number
ml7012-04
Description
2400 Single Chip Full Duplex Data Modem With Protocol
Manufacturer
Oki Optical Components
Datasheet
1 Semiconductor
CMD
%E
&T
\Q
\N
\V
\L
AT%En
AT&Tn
AT\Nn
AT\Qn
AT\Vn
AT\Ln
Style
Controls the loop back test mode.
n = 0: None
n = 1: Starts local analog loop back test (ALB)
n = 2, 3: None
n = 4: Responds to the RDL test requirement
n = 5: Does not respond to the RDL test requirement
n = 6: Starts remote digital loop back test (RDL)
n = 7: Starts RDL self-diagnostic test.
n = 8: Starts ALB self-diagnostic test.
Selects automatic re-training function due to poor incoming
conditions of the receive section.
n = 0: Automatic re-training is invalid.
n = 1: Automatic re-training is valid.
Checks the line type and displays the result.
n = 0: Checks PBX or direct line.
n = 1: Checks pulse or tone line.
Selects data control mode.
n = 0,1: Selects normal mode (without error correction).
n = 2-5: None
n = 6: Selects reliable mode. Disconnects the line when
MNP connection is not available.
n = 7: Selects auto-reliable mode. Connects in normal mode
when MNP connection is not available.
Selects the flow control between DTE and modem.
n = 0: No flow control
n = 1: None
n = 2: None
n = 3: Bi-directional control by CTS/RTS
Selects extended result code.
n = 0: Displays the normal result code.
n = 1: Displays the result code with the mode of the MNP
connection.
n = 2, 3: None
Function
Initial Value
1
7
3
0
FEDL 7012-04-01
ML7012-04
Note
13/22