maapss0111 M/A-COM, maapss0111 Datasheet - Page 2

no-image

maapss0111

Manufacturer Part Number
maapss0111
Description
1.25 W Vsat Power Amplifier 13.75-14.5 Ghz -
Manufacturer
M/A-COM
Datasheet
2
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
1.25 W VSAT Power Amplifier
13.75—14.5 GHz
Electrical Specifications: V
Operating the MAAPSS0111
The MAAPSS0111 is static sensitive. Please handle
with care. To operate the device, follow these steps.
Ramp down or shutdown in reverse order (gate bias
on first and off last).
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.
1. Apply V
2. Apply V
3. Set I
4. Apply RF
Output Return Loss
Input Return Loss
Gain Flatness
Parameter
DQ
Frequency
Duty Cycle
Gate Bias
Stability
Current
Gain
PAE
P
GG
DD
by adjusting V
SAT
IN
(8.0 V Typical).
(-2.0 V).
.
GG
.
DD
= 8 V, I
+2.5V < V
VSWR < 5:1, -40°C < T
Current under saturation
RBW = 3 MHz max hold
DQ
Test Conditions
CC
< +8.0 V, P
= 400 mA, T
Voltage
P
P
I
DQ
SAT
SAT
OUT
C
Compliant
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Absolute Maximum Ratings
3. Exceeding any one or combination of these limits may cause
4. M/A-COM does not recommend sustained operation near
< +85 ºC,
= saturated,
Operating Base Temperature
permanent damage to this device.
these survivability limits.
Operating Supply Voltage
Operating Gate Voltage
Channel Temperature
Storage Temperature
RoHS
A
= 25 °C, Z
Parameter
Input Power
0
Units
dBm
GHz
= 50 :
mA
mA
mA
dB
dB
dB
dB
%
%
V
13.75
Min.
Absolute Maximum
All spurs < -60 dBc
-40°C t o +150° C
-40°C t o +85°C
+10 Volts
+10 dBm
MAAPSS0111
3,4
+160 °C
Typ.
-3 Volts
400
530
-1.9
-16
-12
0.2
34
31
31
1
Max.
14.5
100
—-
V2P