ADE7758 Analog Devices, ADE7758 Datasheet - Page 51

no-image

ADE7758

Manufacturer Part Number
ADE7758
Description
Poly Phase Multifunction Energy Metering IC with Per Phase Information
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADE7758
Manufacturer:
明智类比
Quantity:
20 000
Company:
Part Number:
ADE7758ARW
Quantity:
1 000
Part Number:
ADE7758ARWZ
Manufacturer:
AD
Quantity:
517
Part Number:
ADE7758ARWZ
Manufacturer:
AD
Quantity:
53
Part Number:
ADE7758ARWZ
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADE7758ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADE7758ARWZRL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Step 1: If the values were changed after gain calibration, Step 1,
Step 3, and Step 4 from the gain calibration should be repeated
to configure the LCYCMODE, LINECYC, and MASK registers.
Step 2: Set the test system for I
Step 3: Reset the interrupt status register by reading RSTATUS
(0x1A).
Step 4: Read all xWATHR energy registers (0x01 to 0x03) after
the LENERGY interrupt and store the values.
Step 4a: Read the FREQ (0x10) register if the frequency is
unknown.
Step 5: Set the test system for I
Step 6: Repeat Step 3 and Step 4.
TEST
MIN
, V
, V
READ ALL XVARHR
NOM
STEP 7
XWATTOS FOR ALL
STEP 8
STEP 9
STEP 10
FOR I
REPEAT STEP 3 TO
NOM
AFTER LENERGY
XVARHR, XVAROS
SET UP SYSTEM
WRITE TO ALL
CALIBRATION
CALCULATE
STEP 8 FOR
REGISTERS
, and unity power factor.
, and unity power factor.
FOR STEP 10
XWATTOS
PHASES
TEST
INTERRUPT
PF = 0
Figure 83. Power Offset Calibration Using Line Accumulation
, V
NOM
YES
@
LINECYC AND MASK
STEP 1
STEP 2
STEP 3
STEP 4
REGISTERS AFTER
SET LCYCMODE,
SET UP SYSTEM
FOR I
FOR STEP 10, CALCULATE
XVAROS FOR ALL PHASES
FOR STEP 10, WRITE TO
ALL XVAROS REGISTERS
RESET STATUS
TESTED @ I
REGISTERS
INTERRUPT
REGISTER
READ ALL
XWATTHR
LENERGY
@ PF = 1
TEST
END
Rev. A | Page 51 of 68
, V
NOM
MIN
?
NO
STEP 5
FOR I
SET UP SYSTEM
Step 7: Calculate the value to be written to the xWATTOS
registers according to the following equations.
where Accumulation Time is defined in Equation 43 and
xWATTHRI
xWATTHRI
Step 8: Write to all xWATTOS registers (0x39 to 0x3B).
Step 9: Set the test system for I
(calibrate VAR gain).
Step 10: Repeat Steps 3, 4, and 5.
STEP 6
MIN
PF = 1
Offset
xWATTOS
, V
NOM
@
=
TEST
MIN
xWATTHR
is the value in the energy register at I
is the value in the energy register at I
[
11
FOR STEP 10,
PF = 0
0 :
]
=
I
AccumTime
MIN
×
TEST
I
Offset
I
TEST
MIN
, V
NOM
×
×
I
xWATTHR
, and zero power factor
TEST
4
CLKIN
×
2
ADE7758
I
TEST
29
MIN
TEST
×
.
, and
I
MIN
(53)
(52)

Related parts for ADE7758