AD50MEDICAL EMERSON-NETWORKPOWER [Emerson Network Power], AD50MEDICAL Datasheet

no-image

AD50MEDICAL

Manufacturer Part Number
AD50MEDICAL
Description
Universal AC input
Manufacturer
EMERSON-NETWORKPOWER [Emerson Network Power]
Datasheet
Special Features
• Universal AC input
• Fully regulated output
• EN61000-3-2 compliant
• Input power <74 watts
• Overcurrent and overvoltage
• High efficiency
• High MTBF
• IEC320 AC input receptacle
• Built in EMI filter
• (CISPR 22 Class B)
• AC input fuse
• Complies with One Watt Input
• CE Mark EMC & LVD
CSA
CSA
VDE
CE Mark LVD and EMC
Safety
AD50 Medical
Series
50 Watts
Total Power:
Input Voltage:
# of Outputs:
protection
Energy Star / Blue Angel
Requirement
3 pin (type C6) - AD5012N3LM
2 pin (type C8) - AD5012N2LM
UL
UL 60601-1
60601-1
60601-1
50 Watts
90 - 264 VAC
single
Environmental Specifications
Electrical Specifications
Input
Output
Operating temperature:
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
MTBF demonstrated:
Input ra nge
Frequency
Inrush current
Input current
Efficiency
EMI/RFI
Safety ground
leakage current
Maximum Power (Po)
Hold-up time
Overvoltage protection
Overcurrent protection
Thermal protection
Cable/connector
50 W
17 ms. minimum at full load @ 100 Vac, 47 Hz
16 - 20 V
Latching type, recycle AC to reset.
Output short circuit protection auto recover
Overload protection @ 110 - 120% above maximum rating
105° to 120°C Trip point; output will latch off
DC cable length 2.5 mm center plug
DC plug center +v
DC plug outer -v
90-264 Vac (wide range)
47-63 Hz
60A maximum @ 230VAC, cold start 25C°
2 A maximum
80% typical
FCC Part 15, Class B & EN55022 (CISPR 22) Class B
300μA maximum@ 50/60 Hz, 264 VAC input - AD5012N3L
100μA maximum@ 50/60 Hz, 264 VAC input - AD5012N2L
Designed to meet EN61000-4-2, -4, -5, level 4;
EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3
and EN61000-3-2 Class A
Operating; non-condensing 10% to 90% RH
>300,000 hours at full load and 25°C ambient conditions
5° to +40°C ambient
-40°C to +70°C
RoHS
Embedded Power for
Business-Critical Continuity
AD50 Medical Series
Rev. 03.19.08
1 of 2

Related parts for AD50MEDICAL

AD50MEDICAL Summary of contents

Page 1

AD50 Medical Series 50 Watts Total Power: 50 Watts Input Voltage 264 VAC # of Outputs: single Special Features • Universal AC input • Fully regulated output • EN61000-3-2 compliant • Input power <74 watts • Overcurrent and ...

Page 2

Ordering Information Model Maximum Output Maximum Number Power Voltage Load AD5012N3LM Vdc 4.16 A AD5012N2LM Vdc 4. Peak current lasting 200ms every 3 seconds 25ºC including initial tolerance, line voltage, ...

Related keywords