HFCT-5760ANP

Manufacturer Part Number
HFCT-5760ANP
Description
Single Mode OC-3/STM-1 Small Form Factor Pluggable Transceivers
Manufacturer
HP [Agilent(Hewlett-Packard)]
Datasheet
4
Notes:
1. TX Fault is an open collector/drain output which should be pulled up externally with a 4.7K – 10 KW resistor on the host board to a supply < Vcc + 0.3
2. TX disable input is used to shut down the laser output per the state table below with an external 4.7-10 KW4 pull-up resistor.
3. Mod-Def0,1,2. These are the module definition pins. They should be pulled up with a 4.7-10 KW resistor on the host board to a supply less than VccT
4. LOS (Loss of Signal) is an open collector/drain output which should be pulled up externally with a 4.7K – 10 KW resistor on the host board to a supply
5. VeeR and VeeT may be internally connected within the SFP module
6. RD-/+: These are the differential receiver outputs. They are ac coupled 100 W differential lines which should be terminated with 100 W differential at
7. VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.1 – 3.5 V at the SFP connector pin. The maximum supply
8. TD-/+: These are the differential transmitter inputs. They are ac coupled differential lines with 100 W differential termination inside the module. The
Table 1. Pin-out Table
The pin arrangement and definition of this product meets SFP MSA. Table 1 lists the pin description.
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
V. When high, this output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.8 V.
Low (0 – 0.8 V):
Between (0.8 V and 2.0 V): Undefined
High (2.0 – 3.465 V):
Open:
(0.3 V or VccR + 0.3 V.
Mod-Def 0 is grounded by the module to indicate that the module is present
Mod-Def 1 is clock line of two wire serial interface for optional serial ID
Mod-Def 2 is data line of two wire serial interface for optional serial ID
< VccT,R + 0.3 V. When high, this output indicates the received optical power is below the worst case receiver sensitivity (as defined by the standard
in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.8 V. Please see later section for LOS timing.
the user SERDES. The ac coupling is done inside the module and is thus not required on the host board. The voltage swing on these lines will be
between 370 and 2000 mV differential (185 – 1000 mV single ended) when properly terminated.
current is 300 mA.
ac coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 –
1200 mV single ended).
Name
MOD-DEF2
MOD-DEF1
MOD-DEF0
Rate Select
LOS
RD-
RD+
VeeT
TX Fault
TX Disable
VeeR
VeeR
VeeR
VeeR
VccR
VccT
VeeT
TD+
TD-
VeeT
Transmitter on
Transmitter Disabled
Transmitter Disabled
Function/Description
Module Definition 2 - Two wire serial ID interface
Module Definition 1 - Two wire serial ID interface
Module Definition 0 - Grounded in module
Not Connected
Loss of Signal
Receiver Ground
Receiver Ground
Receiver Ground
Inverse Received Data Out
Received Data Out
Receiver Ground
Receiver Power - 3.3 V ±5%
Inverse Transmitter Data In
Transmitter Ground
Transmitter Fault Indication
Transmitter Disable - Module disables on high or open
Transmitter Power - 3.3 V ±5%
Transmitter Ground
Transmitter Data In
Transmitter Ground
MSA Notes
Note 1
Note 2
Note 3
Note 3
Note 3
Note 4
Note 5
Note 5
Note 5
Note 6
Note 6
Note 5
Note 7
Note 7
Note 5
Note 8
Note 8
Note 5

Related parts for HFCT-5760ANP