FT313HP-R FTDI, FT313HP-R Datasheet - Page 28

no-image

FT313HP-R

Manufacturer Part Number
FT313HP-R
Description
USB Interface IC USB High Speed USB-- Host Controller IC--
Manufacturer
FTDI
Datasheet

Specifications of FT313HP-R

Rohs
yes
Product
USB 2.0
Data Rate
480 Mbps
Interface Type
USB
Operating Supply Voltage
1.62 V to 3.63 V
Operating Supply Current
35 mA
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
TQFP-64
Minimum Operating Temperature
- 40 C

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
FT313HP-R
Manufacturer:
FTDI, Future Technology Devices International Ltd
Quantity:
10 000
Bit
6
[5:4]
3
2
1
0
Name
F_PO_RESM
Reserved
PO_EN_CHG
PO_EN
CONN_CHG
CONN_STS
Copyright © 2012 Future Technology Devices International Limited
Type
R/W
RO
R/WC
R/W
R/WC
RO
Default value
1’b0
2’b00
1’b0
1’b0
1’b0
1’b0
FT313H USB2.0 HS Host Controller Datasheet Version 1.1
Description
The Port Enable Bit and Suspend Bit of this
register define the port state as follows:
Bits[Port Enable, Suspend]
0X
10
11
At the suspend state, the downstream
propagation of the data is blocked on this port,
except for the port reset. While at the suspend
state, the port is sensitive to resume detection.
Writing a ‘0’ to this bit is ignored by the host
controller. The host controller will
unconditionally set this bit to a ‘0’ when:
The software sets Force Port Resume bit to a ‘0’
(From a one)
The software sets Port Reset bit to a ‘1’ (From a
‘0’)
Note: Before setting this bit, RUN/STOP bit
should be set to 0.
Force Port Resume
1 = Resume detected/driven on port.
0 = No resume detected/driven on port.
Software sets this bit to a ‘1’ to resume signal.
The host controller sets this bit to a ‘1’ if a J-to-K
transition is detected while the port is in the
suspend state. When this bit transits to a ‘1’ for
the detection of a J-to-K transition, the Port
Change Detect bit in USBSTS register is also set
to a ‘1’.
-
Port Enable/Disable Change
1 = Port enable/disable status has changed.
0 = No change
Port Enable/Disable
1 = Enable
0 = Disable
Ports can only be enabled by the host controller
as a part of the reset and enable. Software
cannot enable a port by writing a one to this
field.
Connect Status Change
1 = Change current connect status
0 = No change.
This bit indicates a change has occurred in the
current connect status of the port.
Current Connect Status
1 = Device is presented on the port.
0 = No device is presented.
Document No.: FT_000589
Clearance No.: FTDI# 318
Port State
Disable
Enable
Suspend
28

Related parts for FT313HP-R