ADM1028ARQ ON Semiconductor, ADM1028ARQ Datasheet - Page 10

no-image

ADM1028ARQ

Manufacturer Part Number
ADM1028ARQ
Description
IC SENSOR TEMP/FAN CTRL 16QSOP
Manufacturer
ON Semiconductor
Datasheet

Specifications of ADM1028ARQ

Rohs Status
RoHS non-compliant
Function
Fan Control, Temp Monitor
Topology
ADC, Register Bank
Sensor Type
External & Internal
Sensing Temperature
0°C ~ 100°C, External Sensor
Output Type
SMBus™
Output Alarm
No
Output Fan
Yes
Voltage - Supply
3 V ~ 5.5 V
Operating Temperature
0°C ~ 100°C
Mounting Type
Surface Mount
Package / Case
16-QSOP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADM1028ARQ
Manufacturer:
AD
Quantity:
516
Part Number:
ADM1028ARQ
Manufacturer:
AD
Quantity:
20 000
Part Number:
ADM1028ARQZ
Manufacturer:
AD
Quantity:
16 787
Part Number:
ADM1028ARQZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADM1028
FAULT TOLERANT FAN CONTROL
The ADM1028 incorporates a fault tolerant fan control capability
that is tied to operation of the THERMA, THERMB outputs. It
can override the setting of the analog output and force it to maxi-
mum to give full fan speed in the event of a critical over-temperature
problem, even if, for some reason, this has not been handled by
the system software.
There are two temperature set point registers that will activate the
fault tolerant fan control. One of these limits is programmable
by the user and one is a hardware (read-only) register that will
operate if the user does not program any limit. The fault tolerant fan
control is activated if a limit is exceeded for three or more con-
secutive readings. These limits are separate from the normal
high and low temperature limits for the INT output, which do
not affect the fault tolerant fan control or THERM outputs.
A hardware limit of 100∞C is programmed into the register at
address 18h, for the remote diode Default THERM limit. This
is the default limit and the analog output will be forced to full-
scale if the remote sensor reads more than 100∞C. This makes
the fault tolerant fan control fail-safe in that it will operate at
this temperature even if the user has programmed no other limit,
or in the event of a software malfunction. Similarly, the Default
Internal Temp THERM limit held in register 17h, forces the
analog output full-scale if the ambient temperature measured is
more than 70∞C.
The user may override the default limits by programming a new
limit into register 14h for the remote sensor and a new limit into
register 13h for the internal sensor. The default value in register
14h is the same as for the read-only register (100∞C), but it may
be programmed with higher or lower values.
Once registers 13h and 14h have been programmed, or if the
defaults are acceptable, Bit 3 of the configuration register must
be set to “1.” This bit is a write-once bit that can only be writ-
ten to “1,” and it has two effects:
1. It makes the values in registers 13h and 14h the active limits,
2. It locks the data into registers 13h and 14h, so that it cannot
Once the hardware override of the analog output is triggered, it
will only return to normal operation after three consecutive
measurements that are 5 degrees lower than the set limit.
Whenever FAN_SPD output is forced to full-scale, the FAN_OFF
output is negated.
FAN SPEED RAMPING
The ADM1028 device contains a Fan Speed Ramping mecha-
nism that is accomplished using an 8-bit counter and a control
register. On power-up, or an assertion of RST or AUXRST, the
Fan Speed Register, counter, and Fan Speed Ramp Register are
initialized to 0x00. The fan speed ramping mechanism is disabled
by default and any value written to the Fan Speed Register is
immediately reflected on the FAN_SPD output. Setting Bit 0 of
the Fan Speed Ramp Rate Register enables the ramping mechanism.
The counter is then preloaded with the current value contained
in the Fan Speed Register, which prevents the fan speed from
changing until a new value is written to the Fan Speed Register.
and disables read-only registers 17h and 18h.
be changed until the lock bit is reset, either when AUXRST
or RST is asserted, or a Power-On Reset occurs.
–10–
When a new target Fan Speed Value is written to the Fan Speed
Register, the counter begins counting up or down (depending on
whether the current value is greater or less than the target value).
The counter will then count at the rate specified by the ramp rate
bits of the Fan Speed Ramp Register. Once the counter reaches
the target value the counter will stop counting. The FAN_SPD
value is derived from the output of the counter. If a new value is
written to the Fan Speed Register while a ramp function is occur-
ring, the counter may change count direction to reach the new
target value. The operation of THERM is independent of the fan
speed ramping mechanism. Thus, THERM will assert immedi-
ately for over-temperature conditions.
THE ADM1028 INTERRUPT SYSTEM
The ADM1028 has three interrupt outputs, INT, THERMA
and THERMB. These have different functions. INT responds
to violations of software programmed temperature limits and its
interrupt sources are maskable, as described in more detail later.
Interrupts and status bits are only set if a limit is exceeded for at
least three consecutive conversions.
Operation of the INT output is illustrated in Figure 7. Assuming
that the temperature starts off within the programmed limits and
that temperature interrupt sources are not masked, INT will go
low if the temperature measured by the external sensor goes
outside the programmed high or low temperature limit for the
sensor. INT also goes low whenever THERM is low.
Once the interrupt has been cleared, it will not be reasserted even
if the temperature remains outside the limit previously exceeded.
However, INT will be rearmed if the temperature falls back within
the set limits for three consecutive conversions. Once the INT
function has been rearmed, it will then be reasserted once a
limit is exceeded for three consecutive conversions.
FAN SPEED RAMP
RATE REGISTER
100 C
90 C
80 C
70 C
60 C
50 C
40 C
INT
Figure 7. Operation of INT Output
RAMP ENABLE
RAMP RATE
TEMP
*INT CLEARED BY
SOFTWARE
*
(CURRENT SPEED)
Figure 6.
START/STOP
UP/DOWN
COUNTER
FAN SPEED
LOW LIMIT
REGISTER
T
COMPARE
LOGIC REARMED
HIGH
HERE
*
INTERRUPT
HIGH LIMIT
DAC
REV. B
FAN SPD