Datasheets

Specifications of TLP281(GB-TP,F,T)

Number Of Channels
1
Input Type
DC
Voltage - Isolation
2500Vrms
Current Transfer Ratio (min)
100% @ 5mA
Current Transfer Ratio (max)
600% @ 5mA
Voltage - Output
80V
Current - Output / Channel
50mA
Current - Dc Forward (if)
50mA
Vce Saturation (max)
400mV
Output Type
Transistor
Mounting Type
Surface Mount
Package / Case
4-SOP
Configuration
1 Channel
Maximum Collector Emitter Voltage
80 V
Maximum Collector Emitter Saturation Voltage
0.4 V
Isolation Voltage
2500 Vrms
Current Transfer Ratio
100 % to 600 %
Maximum Forward Diode Voltage
1.3 V
Minimum Forward Diode Voltage
1 V
Maximum Power Dissipation
200 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 55 C
Forward Current
10 mA
Maximum Input Diode Current
10 mA
Maximum Reverse Diode Voltage
5 V
Output Device
Phototransistor
Number Of Elements
1
Reverse Breakdown Voltage
5V
Forward Voltage
1.3V
Collector-emitter Voltage
80V
Package Type
SOP
Collector Current (dc) (max)
50mA
Power Dissipation
200mW
Collector-emitter Saturation Voltage
0.4V
Pin Count
4
Mounting
Surface Mount
Operating Temp Range
-55C to 100C
Operating Temperature Classification
Industrial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
TLP281(GB-TP,F)
TLP281GBFTR
9
The above operating life data are estimates extrapolated from long-term light output degradation over a single wafer lot and are
shown as reference only. Operating conditions exceeding the maximum ratings are not guaranteed.
3
3
10000000
1000000
GaA As (DH) LED Projected Light Output Degradation Data
GaA As (DH) LED Projected Operating Life Data
140
120
100
140
120
100
Device Degradation
100000
80
60
40
20
80
60
40
20
10000
0
0
1000
1
1
100
227
2.0
I
I
I
I
I
Failure criteria light output degradation Δ P O < –50%
F
F
F
F
F
150
= 10 mA
= 20 mA
= 30 mA
= 40 mA
= 50 mA
10
10
Test conditions: I
Test conditions: I
100
85
3.0
60
100
100
Test time (h)
Test time (h)
F
F
25
= 50 mA, Ta = 40°C
= 10 mA, Ta = 40°C
1000
1000
0
4.0
I
F
Ambient Temperature (°C)
= 10 mA
I
I
I
I
–30
F
F
F
F
= 20 mA
= 30 mA
= 40 mA
= 50 mA
Projected F50%
operating life
10000
10000
Projected F0.1%
operating life
X-3σ
–50
X-3σ
1 / K(×10
X
X
100000
100000
–73
5.0
−3
)
62
10000000
1000000
140
120
100
100000
80
60
40
20
10000
0
1000
100
1
227
2.0
I
I
I
I
I
150
F
F
F
F
F
Failure criteria light output degradation Δ P O < –30%
= 10 mA
= 20 mA
= 30 mA
= 40 mA
= 50 mA
10
Test conditions: I
100
85
3.0
60
100
Test time (h)
F
25
= 20 mA, Ta = 40°C
1000
0
4.0
Ambient Temperature (°C)
I
I
I
I
I
F
F
F
F
F
–30
= 10 mA
= 20 mA
= 30 mA
= 40 mA
= 50 mA
Projected F0.1%
operating life
Projected F50%
operating life
10000
X-3σ
–50
X
1 / K(×10
100000
–73
5.0
−3
)

Related parts for TLP281(GB-TP,F,T)