NHD-0216HZ-FL-GBW Newhaven Display, NHD-0216HZ-FL-GBW Datasheet - Page 6

LCD MOD CHAR 2X16 Y/G TRANSFL

NHD-0216HZ-FL-GBW

Manufacturer Part Number
NHD-0216HZ-FL-GBW
Description
LCD MOD CHAR 2X16 Y/G TRANSFL
Manufacturer
Newhaven Display
Series
NHD-0216HZ-Fr
Datasheet

Specifications of NHD-0216HZ-FL-GBW

Display Type
STN - Super-Twisted Nematic
Display Mode
Transflective
Number Of Digits/alpha
32
Outline L X W X H
65.50mm x 36.70mm x 13.50mm
Viewing Area
54.00mm L x 14.40mm W
Backlight
LED - Yellow/Green
Display Format
16 x 2
Character Size
4.99mm H x 2.55mm W
Character Format
5 x 8 Dots
Voltage - Supply
5.0V
Dot Size
0.47mm W x 0.58mm H
Operating Temperature
-20°C ~ 70°C
Character Count X Line
16 x 2
Module Size (w X H X T)
65.5 mm x 36.7 mm x 13.5 mm
Fluid Type
STN
Background Color
Gray
Voltage Rating
5 V
Operating Temperature Range
- 20 C to + 70 C
Backlight Type
LED Yellow / Green
Interface
Parallel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Clear
Display
Return
Home
Entry mode
Set
Display ON/
OFF control
Cursor or
Display shift
Function set
Set CGRAM
Address
Set DDRAM
Address
Flag and
Address
Write data to
Address
Read data
From RAM
Instruction Table
NOTE:
necessary for executing the next instruction by the falling edge of the “E” signal after the busy flag (DB7)
goes to “Low”.
Contents
address to “00H” into AC (address counter).
display.
Newhaven Display International, LLC
Instruction
Read busy
1) Clear display
When an MPU program with checking the busy flag (DB7) is made, it must be necessary 1/2fosc is
Clear all the display data by writing “20H” (space code) to all DDRAM address, and set DDRAM
Return cursor to the original status, namely, bring the cursor to the left edge on the fist line of the
Make the entry mode increment (I/D=“High”).
Busy flag check must be preceded by the next instruction.
RS
0
RS
0
0
0
0
0
0
0
0
0
1
1
R/W
0
R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0
0
0
0
0
0
0
0
0
1
0
1
D7
D7
BF AC6 AC5 AC4 AC3 AC2 AC1 AC0
0
0
0
0
0
0
0
1
DB7
0
AC6 AC5 AC4 AC3 AC2 AC1 AC0
D6
D6
0
0
0
0
0
0
1
Instruction code
AC5 AC4 AC3 AC2 AC1 AC0
D5
D5
0
0
0
0
0
1
DB6
0
DL
D4
D4
0
0
0
0
1
D3
D3
S/C R/L
N
DB5
0
0
0
1
0
D2
D2
D
0
0
1
F
5/9
I/D
D1
D1
DB4
C
0
1
-
-
0
SH
D0
D0
1
B
-
-
-
Write “20H” to DDRA and set
DDRAM address to “00H” from
AC
Set DDRAM address to “00H”
From AC and return cursor to
Its original position if shifted.
The contents of DDRAM are not
changed.
Assign cursor moving direction
And blinking of entire display
Set display (D), cursor (C), and
Blinking of cursor (B) on/off
Control bit.
Set cursor moving and display
Shift control bit, and the
Direction, without changing of
DDRAM data.
Set interface data length (DL: 8-
Bit/4-bit), numbers of display
Line (N: =2-line/1-line) and,
Display font type (F: 5x11/5x8)
Set CGRAM address in address
Counter.
Set DDRAM address in address
Counter.
Whether during internal
Operation or not can be known
By reading BF. The contents of
Address counter can also be read.
Write data into internal RAM
(DDRAM/CGRAM).
Read data from internal RAM
(DDRAM/CGRAM).
DB3
0
Description
DB2
0
DB1
0
time (fosc=
Execution
270 KHZ
DB0
1.53ms
1.53ms
1
39us
39us
39us
39us
39us
43us
43us
0us

Related parts for NHD-0216HZ-FL-GBW