ZUP6-33/U TDK Corporation, ZUP6-33/U Datasheet - Page 29

PWR SUP BENCH PROG 0-6V 198W

ZUP6-33/U

Manufacturer Part Number
ZUP6-33/U
Description
PWR SUP BENCH PROG 0-6V 198W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP6-33/U

Voltage - Output
0 ~ 6V
Number Of Outputs
1
Power (watts)
198W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 6 VDC @ 33A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
198W
Operating Temperature
0°C ~ 50°C
Efficiency
72%
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Accuracy
0.02% + 5 mV
Brand/series
ZUP
Current, Output
33 A
Display Type
Digital Meter
Power, Output
198 W
Power, Rating
198 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
6 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1683
ZUP633/U
Table 4-1: Front panel controls and indicators
1
2
3
4
5
9
6
7
8
#
AMPS Display
VOLTS Display
CV Indicator
CC Indicator
ADJUST knob
ALM Indicator
(Rotary pulse generator)
OUT Pushbutton
REM Pushbutton
FOLD Pushbutton
Control/Indicator
Description
Actual output current display at normal operation. While
adjusting the output current, the set value will be shown.
The display will automatically return to show the actual
current approx. 3sec from completion of adjustment.
Actual output voltage display at normal operation. The
measurement circuits monitor the voltage at the sensing
points, hence at remote sensing where there is voltage
drop on the load wires, the voltage at the power supply
output terminals will be higher than the displayed value.
Attention should be taken not to exceed the output power
rating. While adjusting the output voltage, the set value will
be shown. The display will automatically return to show the
actual voltage approx. 3sec after completion of adjustment.
CV LED indicates that the power supply is regulating it’s
output at a constant voltage.
CC LED indicates that the power supply is regulating it’s
output at a constant current.
The ADJUST knob functions to determine the following
output parameters:
1. Output voltage adjust - as determined by V/A pushbutton
2. Output current adjust - as determined by V/A pushbutton
3. Over voltage protection adjust - as determined by
4. Under voltage soft limit adjust-as determined
5. Address selection
ALM indicates alarm caused by activation of one of the
following protections:
* Over voltage protection
* Over temperature protection
* Foldback protection
Main function: Enable or disable the power supply output.
Auxiliary function: Press and hold OUT pushbutton for
approx. 3sec to change function to select between safe
mode restart and automatic restart.
Main function: Select between local or remote operation.
Auxiliary function: Press and hold REM pushbutton for
approx. 3sec to change function to select between RS232
or RS485 communication.
Pressing FOLD pushbutton arms foldback protection
which shuts down output if supply transits from CV to CC.
OVP/UVP pushbutton
by OVP/UVP pushbutton
5.2.1
4.4.2
4.4.3
4.4.5
4.4.6
4.4.7
5.2.4
4.4.8
4.4.9
Par.