ZUP6-33/U TDK Corporation, ZUP6-33/U Datasheet - Page 41

PWR SUP BENCH PROG 0-6V 198W

ZUP6-33/U

Manufacturer Part Number
ZUP6-33/U
Description
PWR SUP BENCH PROG 0-6V 198W
Manufacturer
TDK Corporation
Series
ZUPr
Type
Programmabler
Datasheets

Specifications of ZUP6-33/U

Voltage - Output
0 ~ 6V
Number Of Outputs
1
Power (watts)
198W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
85 ~ 265VAC
Mounting Type
Chassis Mount
1st Output
0 ~ 6 VDC @ 33A
Size / Dimension
13.78" L x 4.88" W x 2.76" H (350mm x 124mm x 70mm)
Power (watts) - Rated
198W
Operating Temperature
0°C ~ 50°C
Efficiency
72%
Approvals
CE, EN, UL
Line Regulation
0.01%
Load Regulation
0.01%
Accuracy
0.02% + 5 mV
Brand/series
ZUP
Current, Output
33 A
Display Type
Digital Meter
Power, Output
198 W
Power, Rating
198 W (Max.)
Regulation, Line
0.01% + 2 mA⁄1 mV + 0.005%
Regulation, Load
0.01% + 5 mA⁄2 mV + 0.005%
Standards
UL Listed, CE Marked
Temperature Coefficient
30 ppm⁄°C (CV)⁄100 ppm⁄°C (CC)
Temperature, Operating, Maximum
50 °C
Temperature, Operating, Minimum
0 °C
Voltage, Input
85-265 VAC
Voltage, Noise
50 mV @ 20 MHz BW
Voltage, Output
6 VDC
Voltage, Ripple
5 mV @ 5 Hz to 1 MHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1683
ZUP633/U
4.4.14 Series Operation
1. GENERAL: Two power supplies of the same rating can be connected in series to increase the
2. Series connection for increased output voltage:
current limits of each power supply to the maximum that the load can handle without damage. It is
recommended to connect diodes in parallel to each unit output to prevent reverse voltage during start-
up condition or in case one of the units shuts down. Each diode should be rated to at least the power
supply’s output current. Refer to Fig: 4-12 and 4-13 for this operating mode.
Fig. 4-12: Series connection with local sensing.
When two power supplies are connected in series, they should be programmed to the same output
2.2 Remote programming at series operation for increased output voltage:
output voltage or to provide bipolar output voltage.
2.1 General: At this operation mode, two units are connected so their outputs are summed. Set the
SUPPLY
SUPPLY
POWER
POWER
is grounded, no point may be at a greater potential ( + or - ) from ground than that specified
When power supplies are connected in series, and the load or one of the output terminals
1. Programming by external voltage; The analog programming circuits of the ZUP power supply
2. Programming by external resistor: Programming by external resistor is possible. Refer to
3. Programming via the communication port (RS232/RS485): The communication port is isolated
are referenced to the - Sense potential. Therefore, the circuits used to control each unit must
be separated and floated from each other.
Fig. 4-5 and Fig. 4-6 for details.
from the output voltage, therefore power supplies connected in series, can be chained using
the Remote-in and Remote-out connectors.
voltage to prevent damage to the lower voltage supply at short circuit condition.
+LS
+LS
- LS
- LS
+S
+S
- S
- S
+
+
_
_
on the front panel marking.
+
_
LOAD
CAUTION
CAUTION
Fig. 4-13: Series connection, remote sensing.
SUPPLY
SUPPLY
POWER
POWER
+LS
+LS
- LS
- LS
+S
+S
- S
- S
+
+
_
_
+
_
LOAD