TOOLSTICK542PP Silicon Laboratories Inc, TOOLSTICK542PP Datasheet - Page 42

PLATFORM PROG TOOLSTICK F542

TOOLSTICK542PP

Manufacturer Part Number
TOOLSTICK542PP
Description
PLATFORM PROG TOOLSTICK F542
Manufacturer
Silicon Laboratories Inc
Series
ToolStickr
Type
Microcontroller Programmerr
Datasheets

Specifications of TOOLSTICK542PP

Contents
2 Boards and USB Connecting Cable
Processor To Be Evaluated
C8051F542
Interface Type
USB
Operating Supply Voltage
2.7 V to 3.6 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
C8051F542
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1718
C8051F54x
SFR Definition 5.7. ADC0CN: ADC0 Control
SFR Address = 0xE8; SFR Page = 0x00; Bit-Addressable
42
Name
Reset
1:0 AD0CM[1:0] ADC0 Start of Conversion Mode Select.
Bit
Type
7
6
5
4
3
2
Bit
BURSTEN ADC0 Burst Mode Enable Bit.
AD0BUSY ADC0 Busy Bit.
AD0WINT
AD0LJST
AD0INT
AD0EN
Name
AD0EN
R/W
7
0
ADC0 Enable Bit.
0: ADC0 Disabled. ADC0 is in low-power shutdown.
1: ADC0 Enabled. ADC0 is active and ready for data conversions.
0: Burst Mode Disabled.
1: Burst Mode Enabled.
ADC0 Conversion Complete Interrupt Flag.
0: ADC0 has not completed a data conversion since AD0INT was last cleared.
1: ADC0 has completed a data conversion.
ADC0 Window Compare Interrupt Flag.
This bit must be cleared by software
0: ADC0 Window Comparison Data match has not occurred since this flag was last
cleared.
1: ADC0 Window Comparison Data match has occurred.
ADC0 Left Justify Select Bit.
0: Data in ADC0H:ADC0L registers is right-justified
1: Data in ADC0H:ADC0L registers is left-justified. This option should not be used
with a repeat count greater than 1 (when AD0RPT[1:0] is 01b, 10b, or 11b).
00: ADC0 start-of-conversion source is write of 1 to AD0BUSY.
01: ADC0 start-of-conversion source is overflow of Timer 1.
10: ADC0 start-of-conversion source is rising edge of external CNVSTR.
11: ADC0 start-of-conversion source is overflow of Timer 2.
BURSTEN
R/W
6
0
AD0INT
R/W
5
0
AD0BUSY AD0WINT AD0LJST
R/W
Rev. 1.1
4
0
Read:
0: ADC0 conversion is not
in progress.
1: ADC0 conversion is in
progress.
Function
R/W
3
0
R/W
2
0
Write:
0: No Effect.
1: Initiates ADC0 Conver-
sion if AD0CM[1:0] = 00b
1
0
AD0CM[1:0]
R/W
0
0

Related parts for TOOLSTICK542PP