P2CF-08-E Omron, P2CF-08-E Datasheet - Page 30

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
Timing Charts
Twin Timer Operation
The gate input is not included in the H5CX-L8@ models.
Self-diagnostic Function
The following displays will appear if an error occurs.
Note: This includes times when the life of the EEPROM has expired.
Sustained
Output
Sustained
Output
e1
e2
e2
Timing
diagram
Timing
diagram
Main display
Control output
Control output
Start signal
UP
DOWN
Start signal
UP
DOWN
OFF time
OFF time
ON time
ON time
OFF time
OFF time
ON time
ON time
Power
Reset
Reset
Gate
Power
Gate
0
0
0
0
Not lit
Not lit
sum
Sub-display
CPU
Memory error (RAM)
Memory error (EEP)
(See note)
Error
Output mode toff: Flicker OFF start
Output mode ton: Flicker ON start
OFF
OFF
OFF
Output status
Either press the reset key or reset the
power supply.
Reset the power supply.
Reset to the factory settings using
the reset key.
Correction method
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (OFF at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Start signal
input
*
**
Timing starts when the start signal goes ON.
The status of the control output is reversed when time
is up (ON at start).
While the start signal is ON, the timer starts when the
power comes ON or when the reset input goes OFF.
Start signal
input
*
**
Output
Output
Basic Operation
Power
Basic Operation
Power
Normal output operation will not be possible if the
ON/OFF set time is too short.
Set the value to at least 100 ms (contact output
type).
Start signal input is disabled during timing.
Normal output operation will not be possible if the
ON/OFF set time is too short.
Set the value to at least 100 ms (contact output
type).
Start signal input is disabled during timing.
**
**
Timing
OFF
Timing
ON
Timing
OFF
Timing
ON
H5CX-A/-L
No change
No change
0
Timing
OFF
Timing
ON
Set value after
reset
Timing
OFF
Timing
ON
30

Related parts for P2CF-08-E