P2CF-08-E Omron, P2CF-08-E Datasheet - Page 46

SOCKET 8-PIN FOR H3CR-H

P2CF-08-E

Manufacturer Part Number
P2CF-08-E
Description
SOCKET 8-PIN FOR H3CR-H
Manufacturer
Omron
Type
Socketr

Specifications of P2CF-08-E

Number Of Positions
8
Mounting Type
DIN Rail
Termination Style
Screw Terminal
Size
70 mm x 50 mm x 19 mm
Socket Mounting
DIN Rail
Socket Terminals
Screw
Voltage Rating
240VAC
No. Of Pins
8
Accessory Type
Finger Safe Terminal
Rohs Compliant
Yes
Number Of Poles
8
Mounting Style
DIN Rail
For Use With/related Products
Multiple Series
For Use With
Z3000 - RELAY TIMER DGTL SPDT 12-24VDCZ2999 - RELAY TIMER DGTL SPDT 100/240VACH3CR-A8E AC100-240/DC100-125 - RELAY ANALOG SET DPDT 8PINZ2815 - RELAY REPEAT CYCLE ANALOG 30HRSZ2387 - RELAY TIMER 0-12SEC OFF-DELAYZ2386 - RELAY TIMER 0-12MIN OFF-DELAYZ2385 - RELAY REPEAT CYCLE ANALOG 30HRSZ2384 - RELAY REPEAT CYCLE ANALOG 300HRSZ2381 - RELAY ANALOG SET DPDT 8PINZ2380 - RELAY ANALOG SET DPDT 8PINZ2379 - RELAY ANALOG SET DPDT 8PINZ2382 - RELAY REPEAT CYCLE ANLG 30HRS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
P2CF-08-E
P2CF08E
Z2836

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P2CF-08-E
Manufacturer:
Omron Electronics Inc-IA Div
Quantity:
135
■ Timing Charts
Note: Forecast Value = Set Value − Forecast Set Value
■ Self-diagnostic Function
The following displays will appear if an error occurs.
Note: This includes times when the life of the EEPROM has expired.
e1
e2
e2
Forecast value (SV 1)
Forecast value (SV 1)
Main display
Set value (SV 2)
Set value (SV 2)
The forecast set value is used to set the deviation for the set value.
Start signal
Start signal
Power
999999
Reset
Gate
OUT1
OUT2
999999
Power
Reset
OUT1
OUT2
Gate
0
0
The names in parentheses are used for the absolute value setting.
The names in parentheses are used for the absolute value setting.
Not lit
Not lit
sum
Sub-display
F-1 mode: Cumulative (Timer does not reset when power comes ON.)
A Mode: Signal ON delay (Timer resets when power comes ON.)
CPU
Memory error (RAM)
Memory error (EEP)
(See note)
Error
OFF
OFF
OFF
Output status
Either press the reset key or reset the
power supply.
Reset the power supply.
Reset to the factory settings using
the reset key.
(Control output 2)
Start signal input
(Control output 2)
(Control output 1)
Basic Operation
*
**
(Control output 1)
Start signal input
Basic Operation
*
Forecast output
Forecast output
Correction method
Timing starts when the start signal turns ON.
While the start signal is ON, the timer starts when the power
turns ON or when the reset input turns OFF.
A sustained control output is used.
Timing stops when the time is up.
Control output
Control output
Output is instantaneous when the set value is 0.
Output is instantaneous when the set value is 0.
Start signal input is disabled during timing.
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
A sustained control output is used.
Timing continues even after the time is up.
Power
OUT2
OUT2
OUT1
Power
OUT1
**
The names in parentheses are used for the
absolute value setting.
The names in parentheses are used for
the absolute value setting.
Timing
Sustained
Timing
No change
No change
0
Set value after
H5CX-B
Timing
reset
46

Related parts for P2CF-08-E