NRH3012T100MN Taiyo Yuden, NRH3012T100MN Datasheet - Page 20

no-image

NRH3012T100MN

Manufacturer Part Number
NRH3012T100MN
Description
INDUCTOR 10UH .72A 20% SMD
Manufacturer
Taiyo Yuden
Series
NRHr
Datasheet

Specifications of NRH3012T100MN

Inductance
10µH
Current
720mA
Current - Saturation
730mA
Current - Temperature Rise
720mA
Tolerance
±20%
Shielding
Unshielded
Dc Resistance (dcr)
324 mOhm Max
Self Resonant Freq
32MHz
Package / Case
0.118" L x 0.118" W x 0.047" H (3.00mm x 3.00mm x 1.20mm)
Mounting Type
Surface Mount
Operating Temperature
-25°C ~ 120°C
Frequency - Test
100kHz
Applications
Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Q @ Freq
-
Other names
587-2584-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NRH3012T100MN
Manufacturer:
TAIYO
Quantity:
40 000
Part Number:
NRH3012T100MN
Manufacturer:
TAIYO YUDEN
Quantity:
66 000
Part Number:
NRH3012T100MN
Manufacturer:
TAIYO
Quantity:
8 000
Part Number:
NRH3012T100MN(1012-17-024C)
Manufacturer:
TAIYOYDEN
Quantity:
724
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
wound0103_reli_e-01
20.High temperature life test
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM Series
LEM Series
21.Loading at high temperature life test
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM, LEM Series
22.Low temperature life test
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM Series
LEM Series
23.Standard condition
LB, LBC, LBR, LBMF Series
CB, CBC, CBL, CBMF Series
LBM, LEM Series
Temperature:85±2℃
Duration:1000 hrs
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
LEM:Recovery
At least 1 hr of recovery under the standard condition after the test, followed by the measurement within 2 hrs.
Temperature:85±2℃
Duration:1000 hrs
Applied current:Rated current
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
Temperature:-40±2℃
Duration:1000 hrs
Recovery:At least 2 hrs of recovery under the standard condition after the test, followed by the measurement within 48 hrs.
LEM:Recovery
At least 1 hr of recovery under the standard condition after the test, followed by the measurement within 2 hrs.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
RELIABILITY DATA
Inductance change:Within±10%
Inductance change :Within±10%
Q→ R12~4R7:30 min.
Inductance change:Within±10%
Inductance change:Within±10%
Inductance change :Within±10%
Q→ R12~4R7:30 min.
Standard test conditions
Unless specified, Ambient temperature is 20±15℃ and the Relative humidity is 65±
20%. If there is any doubt about the test results, further measurement shall be had
within the following limits:
Inductance value is based on our standard measurement systems.
Ambient Temperature: 20±2℃
Relative humidity: 65±5%
5R6~330:25 min.
390~820:20 min.
101:15 min.
5R6~330:25 min.
390~820:20 min.
101:15 min.
1 1
No significant abnormality in appearance.
No significant abnormality in appearance.
No significant abnormality in appearance.
wound0103_reli-PRP5

Related parts for NRH3012T100MN