LHL13NB331K Taiyo Yuden, LHL13NB331K Datasheet - Page 19

no-image

LHL13NB331K

Manufacturer Part Number
LHL13NB331K
Description
INDUCTOR 330UH 1.1A RADIAL
Manufacturer
Taiyo Yuden
Series
LHr
Datasheet

Specifications of LHL13NB331K

Inductance
330µH
Current
1.1A
Tolerance
±10%
Dc Resistance (dcr)
350 mOhm Max
Q @ Freq
30 @ 796kHz
Self Resonant Freq
1.8MHz
Package / Case
Radial
Mounting Type
Through Hole
Operating Temperature
-25°C ~ 105°C
Frequency - Test
796kHz
Applications
General Purpose
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Shielding
-
Current - Saturation
-
Current - Temperature Rise
-
24.Damp heat
25.Loading under damp heat
26.Loading at high temperature
RELIABILITY DATA 
当社カタログをご使用の際には 「当社製品に関するお断り」 を必ずお読みください。
Item
△L/L:
Within±10%
Q:30min.
△L/L:
Within±10%
Q:30min.
△L/L:
Within±10%
Q:30min.
FA02
Type
△L/L:
Within±10%
△L/L:
Within±10%
△L/L:
Within±10%
CAL45
Type
(LHLP:
Appearance:
No
abnormality
Imductance
change:
Within±10%
Q change:
Within±30%
only △L/L)
LHL□□□
Specified Value
Appearance:
No
abnormality
Impedance
change:
Within±20%
FBA/FBR
Refer to
individual
specification
FL05□
Type
Appearance:
No
abnormality
Impedance
change:
Within±20%
FL06BT
Type
Please read the "Notice for TAIYO YUDEN products" before using this catalog.
FA・CA:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:1000 hrs
Recovery : At least 1hr of recovery under the standard
FB:
Temperature:60±2℃
Humidity:90∼95%RH
Duration:1000 hrs
Recovery:1 to 2hrs of recovery under the standard condition
FA・CA:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:1000 hrs
Applied current:Rated current
Recovery : At least 1hr of recovery under the standard
LHL□□□:
Temperature:40±2℃
Humidity:90∼95%RH
Duration:1000±24 hrs
Applied current:Rated current
Recovery:1 to 2hrs of recovery under the standard condition
FL:
Temperature:60±3℃
Humidity:90∼95%RH
Duration:500 (+12, ー0) hrs
Applied current:Rated current
Recovery:1 to 2hrs of recovery under the standard condition
FA・CA:
Temperature:85±2℃
Duration:1000 hrs
Applied current:Rated current
Recovery : At least 1hr of recovery under the standard
removal from test chamber, followed by the
measurement within 2hrs.
after the removal from the test cfamber.
removal from test chamber, followed by the
measurement within 2hrs.
after the removal from the test cfamber.
after the removal from the test cfamber.
removal from test chamber, followed by the
measurement within 2hrs.
Test Method and Remarks
8/9
337
5