ATTINY13-20MU Atmel, ATTINY13-20MU Datasheet - Page 118

IC MCU AVR 1K FLASH 10MHZ 20-MLF

ATTINY13-20MU

Manufacturer Part Number
ATTINY13-20MU
Description
IC MCU AVR 1K FLASH 10MHZ 20-MLF
Manufacturer
Atmel
Series
AVR® ATtinyr
Datasheets

Specifications of ATTINY13-20MU

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
6
Program Memory Size
1KB (512 x 16)
Program Memory Type
FLASH
Eeprom Size
64 x 8
Ram Size
64 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
20-MLF®, QFN
Processor Series
ATTINY1x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
64 B
Interface Type
SPI
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
6
Number Of Timers
2
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVRDRAGON, ATSTK500, ATSTK600, ATAVRISP2, ATAVRONEKIT, ATAKSTK511
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 4 Channel
Package
20MLF EP
Device Core
AVR
Family Name
ATtiny
Maximum Speed
20 MHz
For Use With
ATSTK600-DIP40 - STK600 SOCKET/ADAPTER 40-PDIP770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAGATAVRDRAGON - KIT DRAGON 32KB FLASH MEM AVRATAVRISP2 - PROGRAMMER AVR IN SYSTEMATJTAGICE2 - AVR ON-CHIP D-BUG SYSTEM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Connectivity
-
Lead Free Status / Rohs Status
 Details
18.4
18.4.1
Table 18-2.
18.4.2
Table 18-3.
118
Calibration
Method
Factory
Calibration
User
Calibration
Symbol
1/t
t
t
t
t
t
Δ
CLCL
CHCX
CLCX
CLCH
CHCL
t
CLCL
CLCL
Clock Characteristics
ATtiny13
Calibrated Internal RC Oscillator Accuracy
External Clock Drive
Parameter
Clock Frequency
Clock Period
High Time
Low Time
Rise Time
Fall Time
Change in period from one clock cycle to the next
Calibration Accuracy of Internal RC Oscillator
External Clock Drive
4 – 5 MHz / 8 – 10 MHz
Fixed frequency within:
Target Frequency
It is possible to manually calibrate the internal oscillator to be more accurate than default factory
calibration. Note that the oscillator frequency depends on temperature and voltage. Voltage and
temperature characteristics can be found in
148,
ure 19-55 on page
Notes:
Figure 18-3. External Clock Drive Waveform
4.8 / 9.6 MHz
Figure 19-52 on page
1. Accuracy of oscillator frequency at calibration point (fixed temperature and fixed voltage).
2. Voltage range for ATtiny13V.
3. Voltage range for ATtiny13.
V
IL1
V
IH1
150.
Fixed voltage within:
1.8V – 5.5V
2.7V – 5.5V
149,
V
3V
CC
Figure 19-53 on page
V
Min.
250
100
100
(2)
(3)
CC
0
= 1.8 - 5.5V
Max.
2.0
2.0
Figure 19-50 on page
4
2
Fixed temperature
-40°C to +85°C
Temperature
V
within:
Min.
25°C
100
CC
40
40
149,
0
= 2.7 - 5.5V
Figure 19-54 on page
Max.
1.6
1.6
10
2
148,
Accuracy at given Voltage
V
Min.
CC
50
20
20
0
Figure 19-51 on page
& Temperature
= 4.5 - 5.5V
±10%
±2%
Max.
0.5
0.5
20
2535J–AVR–08/10
150, and
2
(1)
Units
MHz
ns
ns
ns
µs
µs
%
Fig-

Related parts for ATTINY13-20MU