ATMEGA329P-20MN Atmel, ATMEGA329P-20MN Datasheet - Page 307

IC MCU AVR 32K 20MHZ 64QFN

ATMEGA329P-20MN

Manufacturer Part Number
ATMEGA329P-20MN
Description
IC MCU AVR 32K 20MHZ 64QFN
Manufacturer
Atmel
Series
AVR® ATmegar
Datasheets

Specifications of ATMEGA329P-20MN

Core Processor
AVR
Core Size
8-Bit
Speed
20MHz
Connectivity
SPI, UART/USART, USI
Peripherals
Brown-out Detect/Reset, LCD, POR, PWM, WDT
Number Of I /o
54
Program Memory Size
32KB (16K x 16)
Program Memory Type
FLASH
Eeprom Size
1K x 8
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-MLF®, 64-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
27.7.7
27.7.8
27.7.9
27.7.10
8021G–AVR–03/11
Reading the EEPROM
Programming the Fuse Low Bits
Programming the Fuse High Bits
Programming the Extended Fuse Bits
The algorithm for reading the EEPROM memory is as follows (refer to
on page 303
1. A: Load Command “0000 0011”.
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. Set OE to “0”, and BS1 to “0”. The EEPROM Data byte can now be read at DATA.
5. Set OE to “1”.
The algorithm for programming the Fuse Low bits is as follows (refer to
on page 303
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Give WR a negative pulse and wait for RDY/BSY to go high.
The algorithm for programming the Fuse High bits is as follows (refer to
Flash” on page 303
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Set BS1 to “1” and BS2 to “0”. This selects high data byte.
4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. Set BS1 to “0”. This selects low data byte.
The algorithm for programming the Extended Fuse bits is as follows (refer to
Flash” on page 303
1. 1. A: Load Command “0100 0000”.
2. 2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. 3. Set BS1 to “0” and BS2 to “1”. This selects extended data byte.
4. 4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. 5. Set BS2 to “0”. This selects low data byte.
for details on Command and Address loading):
for details on Command and Data loading):
for details on Command and Data loading):
for details on Command and Data loading):
ATmega329P/3290P
”Programming the Flash”
”Programming the Flash”
”Programming the
”Programming the
307

Related parts for ATMEGA329P-20MN