Specifications of ACPL-782T-500E

Amplifier Type
Isolation
Number Of Circuits
1
Output Type
Differential
-3db Bandwidth
100kHz
Voltage - Input Offset
300µV
Current - Supply
10.86mA
Current - Output / Channel
18.6mA
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-SMD Gull Wing
No. Of Amplifiers
1
Isolation Voltage
891V
Gain Non-linearity Max
2%
Slew Rate
1500V/µs
Supply Voltage Range
4.5V To 5.5V
Input Offset Voltage
300µV
Bandwidth
100kHz
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Gain Bandwidth Product
-
Current - Input Bias
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-782T-500E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
ACPL-782T-500E
Quantity:
105
IEC 60747-5-5, DIN EN 60747-5-2(VDE 0884 Teil 2) Insulation Characteristics
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits within the
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC
3. Refer to the following figure for dependence of PS and IS on ambient temperature.
4
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
100% Production Test with t
Input to Output Test Voltage, Method a
Type and Sample Test, t
Highest Allowable Overvoltage (Transient Overvoltage t
Safety-limiting values—maximum values allowed in the event of a failure.
Insulation Resistance at T
application. Surface Mount Classification is Class A in accordance with CECC00802.
60747-5-5/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
for rated mains voltage 300 Vrms
for rated mains voltage 450 Vrms
for rated mains voltage 600 Vrms
Case Temperature
Input Current
Output Power
800
700
600
500
400
300
200
100
0
0
25
[3]
[3]
50
T
A
m
- CASE TEMPERATURE - °C
S
= 60 sec, Partial discharge < 5 pC
75
, V
m
IO
= 1 sec, Partial discharge < 5 pC
= 500 V
100
P
I
S
125
S
[2]
(mA)
[2]
(mW)
V
V
IORM
IORM
150
x 1.6 = V
x 1.875 = V
175
PR
ini
200
,
= 60 sec)
PR
,
Symbol
V
V
V
V
T
I
P
R
S,INPUT
S
IORM
PR
PR
IOTM
S,OUTPUT
S
Characteristic
I-IV
I-III
I-II
55/125/21
2
891
1670
1426
6000
175
400
600
>10
9
Unit
V
V
V
V
°C
mA
mW
:
PEAK
PEAK
PEAK
PEAK

Related parts for ACPL-782T-500E