X40410S8I-B Intersil, X40410S8I-B Datasheet - Page 5

no-image

X40410S8I-B

Manufacturer Part Number
X40410S8I-B
Description
IC VOLTAGE MON DUAL W/SUP 8-SOIC
Manufacturer
Intersil
Type
Multi-Voltage Supervisorr
Datasheet

Specifications of X40410S8I-B

Number Of Voltages Monitored
2
Output
Open Drain, Push-Pull
Reset
Active High/Active Low
Reset Timeout
Adjustable/Selectable
Voltage - Threshold
2.6V, 4.4V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
8-SOIC (3.9mm Width)
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Resetting the V
To reset a V
age (Vp) to the WDO pin before a START condition is
set up on SDA. Next, issue on the SDA pin the Slave
Address A0h followed by the Byte Address 03h for
V
Data Byte in order to reset V
lowing a valid write operation initiates the program-
ming sequence. Pin WDO must then be brought LOW
to complete the operation.
After being reset, the value of V
nal value of 1.7V or lesser.
Note: This operation does not corrupt the memory
array.
CONTROL REGISTER
The Control Register provides the user a mechanism for
changing the Block Lock and Watchdog Timer settings.
The Block Lock and Watchdog Timer bits are nonvolatile
and do not change when power is removed.
The Control Register is accessed with a special pream-
ble in the slave byte (1011) and is located at address
1FFh. It can only be modified by performing a byte write
Figure 4. Sample V
TRIP1
V
Adj.
TRIP1
and 0Bh for V
TRIPx
TRIPx
voltage, apply the programming volt-
TRIP
V
Adj.
Voltage
TRIP2
TRIP2
Reset Circuit
5
V2FAIL
, followed by 00h for the
TRIPx
TRIPx
RESET
. The STOP bit fol-
4.7K
becomes a nomi-
X40410, X40411, X40414, X40415
1
3
2
4
X4041x
SOIC
operation directly to the address of the register and only
one data byte is allowed for each register write operation.
Prior to writing to the Control Register, the WEL and
RWEL bits must be set using a two step process, with
the whole sequence requiring 3 steps. See "Writing to
the Control Registers" on page 7.
The user must issue a stop, after sending this byte to
the register, to initiate the nonvolatile cycle that stores
WD1, WD0, PUP1, PUP0, BP1, and BP0. The
X40410/11/14/15 will not acknowledge any data bytes
written after the first byte is entered.
The state of the Control Register can be read at any
time by performing a random read at address 01Fh,
using the special preamble. Only one byte is read by
each register read operation. The master should sup-
ply a stop condition to be consistent with the bus pro-
tocol, but a stop is not required to end this operation.
RWEL: Register Write Enable Latch (Volatile)
The RWEL bit must be set to “1” prior to a write to the
Control Register.
PUP1 WD1 WD0
8
7
6
5
7
6
5
Adjust
Run
BP
4
V
P
3
0
SCL
SDA
RWEL WEL PUP0
2
µC
1
March 28, 2005
FN8116.0
0