E3X-NA6

Manufacturer Part Number
E3X-NA6
Description
CONN READY NPN GEN PURPOSE FO
Manufacturer
Omron
Series
E3X-NAr
Datasheets

Specifications of E3X-NA6

Amplifier Type
Wire Saving
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
35mA
Mounting Type
DIN Rail
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNA6
E3XNA6Q
E3X-NA
Connection
Do not pull or press the Fiber Units. The Fiber Units have a with-
stand force of 9.8 N or 29.4 N maximum (pay utmost attention
because the fibers are thin).
Do not bend the edge of the Fiber Units (excluding the E32-T@R
and E32-D@R).
Do not apply excess force on the Fiber Units.
The Fiber Head could be broken by excessive vibration.Use the
following method to prevent fiber head breakage:
Bending Radius
E39-F11 Sleeve Bender
The bending radius of the stainless steel tube should be as large
as possible. The smaller the bending radius becomes, the shorter
the sensing distance will be.
Insert the tip of the stainless steel tube to the Sleeve Bender and
bend the stainless steel tube slowly along the curve of the Sleeve
Bender (refer to the figure).
R 7.5 mm
Correct
Correct
R 12.5 mm
Amplifier Unit
1.2-mm
dia. max.
1.3-mm dia. min.
Fiber Unit
A one-turn loop can
absorb vibrations.
Nylon wireholder
20 mm min.
Stainless
steel tube
20 mm min.
Fiber Unit
90° max.
R 10 mm
Fiber tip position mark
R 5 mm
Tape
Incorrect
Incorrect
10 mm
Do not bend here.
10 mm
I
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit
2. Join Amplifier Units together as required after all the Master
3. Attach the stickers (provided as accessories) to the sides of
Note:
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to be
2. After the Amplifier Unit has been separated, press down on
Mounting Amplifier Units with
Connectors
until it clicks into place.
and Slave Connectors have been inserted.
Master and Slave Connectors that are not connected to other
Connectors.
removed away from the rest of the group.
the lever on the Connector and remove it. (Do not attempt to
remove Connectors without separating them from other
Amplifier Units first.)
Attach the stickers to the sides with grooves.
Sticker
Press down
Insert
Sticker
Remove
Lever
E3X-NA
15