E3X-NT41 Omron, E3X-NT41 Datasheet - Page 7

AUTOTUNE PNP

E3X-NT41

Manufacturer Part Number
E3X-NT41
Description
AUTOTUNE PNP
Manufacturer
Omron
Series
E3X-Nr
Type
Auto-Tuning Fiber-Optic Sensorr
Datasheet

Specifications of E3X-NT41

Output Type
PNP
Amplifier Type
General Purpose
Voltage - Supply
12 V ~ 24 V
Current - Supply
50mA
Mounting Type
DIN Rail
Sensor Output
PNP
Switch Terminals
Cable
Peak Reflow Compatible (260 C)
No
Sensor Housing
Rectangular
Sensor Input
Fiber Optic
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Lead free / RoHS Compliant
Other names
E3XNT41

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NT41
Manufacturer:
Omron Electronics
Quantity:
135
E3X-N
J NO-OBJECT TEACHING
Note: 1. To detect dark objects in front of bright backgrounds, set the operation mode selector to D. ON.
J SENSITIVITY ADJUSTMENT
Combination of the E3X-NT/E3X-NM and Fine Through-beam Fiber Units (E32-T22S/T24S/T84S)
No-object Teaching
Press the teaching button once with no object in the sensing area.
Note: If detection is not stable after no-object teaching, perform
With/Without-object Teaching
Press the teaching button once with no object in the sensing area.
Procedure
1
2
3
4
5
6
2. If the set distance is very short (i.e., 0 to 12 mm for the E32-TC200 and 0 to 4 mm for the E32-DC200), no-object teaching is
3. If the teaching button is pressed for more than three seconds, the sensitivity of the E3X-Nj will be set to maximum, at which
4. The E3X-Nj will be ready to detect objects in approximately one second after the mode selector is set to RUN.
with/without-object teaching.
not possible due to excessive light, in which case, perform with/without-object teaching.
time the green indicator will be lit.
Operation
Locate the sensor head within the rated sensing range with the E3X-Nj.
Set the mode selector to TEACH.
The flashing function of the E3X-Nj will be activated. Therefore,
adjust the optical axes so that the tip of the emitting fiber will be lit. If
the optical axes are divergent, the tip of the emitting fiber will flash
and the built-in buzzer of the E3X-Nj will beep.
Press the teaching button for 0.5 to 2.5 seconds without a sensing
object. In the case the E3X-NM, select a channel with the channel
selector and press the teaching button, at which time the stability
indicator for the selected channel will flash.
The teaching indicator (red) is lit.
The built-in buzzer beeps once.
Set the mode selector to RUN. No-object teaching will be set when
the first sensing object passes through the sensing area.
The teaching indicator (red) turns green (automatically turned off in
one second).
Select the logical output required with the operation mode selector.
Object
8
E3X-NT
---
TEACH
TEACH
TEACH
RUN
RUN
L
D
ON
ON
E3X-NM
L ON
D ON
TEACH
TEACH
CH
TIMER
TIMER
RUN
RUN
SET
SET
1
TEACH
2 3 4
E3X-N