E2CY-T11 Omron, E2CY-T11 Datasheet - Page 11

AMP 12-24VDC 3-WIRE NPN FOR E2CY

E2CY-T11

Manufacturer Part Number
E2CY-T11
Description
AMP 12-24VDC 3-WIRE NPN FOR E2CY
Manufacturer
Omron
Series
E2CYr
Datasheets

Specifications of E2CY-T11

Amplifier Type
Standard
Voltage - Supply
12 V ~ 24 V
Output Type
NPN
Current - Supply
40mA
Mounting Type
Bracket Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E2CYT11
J AMPLIFIER UNIT
Nomenclature
J CONTROL PANEL OF AMPLIFIER UNIT
J SELF-DIAGNOSTIC FUNCTION
The output transistor of self-diagnostic output will turn ON in the following cases.
1. Sensor cable disconnection
2. Sensor cable short-circuit
3. Control output short-circuiting
4. Internal memory error
E2CY-T11
E2CY
Operation indicator (orange)
Fine-tuning indicator (green)
The self-diagnostic output will turn ON approximately 105 ms after the sensor cable disconnects.
The self-diagnostic output will turn ON approximately 105 ms after the sensor cable short-circuits.
The self-diagnostic output will turn ON if excessive current flows to the load due to load wire short-circuiting.
When the E2CY is turned ON in RUN or TEACH mode, the self-diagnostic output will turn ON if the teaching status of the E2CY is not
stored properly in the internal memory.
Sensor Head mounting side
Output mode selector
Resolution selector
Cable extension side
Note: Sensor mounting screws, M2.6
(0.85)
21.6
(0.39)
Excess gain level
indicators (green)
Excess gain level
indicators (orange)
10
TEACH button
Sensor mounting
screw (M2.6)
Operation mode selector
(0.08)
(0.16)
2
4
(1.28)
32.5
(0.16)
4.1
Two, 3.2-dia. mounting holes
(0.01)
(0.02)
0.2
0.5
Operation indicator
(0.94)
24
(0.87)
(0.97)
22.2
24.6
(1.31)
33.4
(1.31)
Operation Mode Selector
AUTO Mode: The sensitivity is automatically adjusted within
T Mode:
RUN Mode:
Resolution Selector
If the E2CY often has a teaching error when detecting
fine-tuning differences, set the resolution selector to FINE.
The response speed will drop but improvement in the
sensing accuracy of the E2CY can be expected.
Output Mode Selector
Used to select the transistor mode (NPN open collector output).
NO: Normally open output
NC: Normally closed output
33.4
(0.13)
3.4
(Output transistor will turn ON if a sensing object is
present.)
(Output transistor will turn ON if a sensing object is
not present.)
(0.61)
15.5
Excess gain level indicator
(1.37)
34.8
(0.63)
(2.76)
(0.63)
(0.17)
16
70
a range of approximately 80% to 110% of the
rated sensing distance.
This mode is used when adjusting the
sensitivity of the Sensor. (The output transistor
does not operate in this mode.)
This mode is used for the normal operation of
the Sensor.
16
4.4
Fine-tuning indicator
Two, mounting holes
(0.41)
10.5
Mounting bracket
(0.16)
4
(0.09)
2.4
(0.24)
6
Vinyl-insulated round coaxial cable with
4 dia. (18/0.12) with four conductors
Standard length: 2 m
(0.42)
10.6
(0.28)
7
Mounting Holes
Two, M3
(0.63)
16
E2CY
11

Related parts for E2CY-T11