QUAD AUTOTUNE PNP RMT TCH

E3X-NM41

Manufacturer Part Number
E3X-NM41
Description
QUAD AUTOTUNE PNP RMT TCH
Manufacturer
Omron
Series
E3X-Nr
Type
Fiber Optic Sensorr
Datasheets

Specifications of E3X-NM41

Output Type
PNP
Amplifier Type
Four Channel
Voltage - Supply
12 V ~ 24 V
Current - Supply
150mA
Mounting Type
DIN Rail
Length/height, External
33mm
Response Time
1ms
Sensor Input
Fiber Optic
External Width
32.2mm
External Depth
59mm
Operating Temperature Min
-25°C
Operating Temperature Max
55°C
Output Current Max
100mA
Rohs Compliant
Yes
Fiber Optic Sensor Type
Fiber Optic Sensor
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
E3XNM41

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
E3X-NM41
Manufacturer:
EVERLIGHT
Quantity:
20 390
J WITH/WITHOUT-OBJECT TEACHING
Note: 1. Even if the E3X-Nj is turned off, the E3X-Nj will retain the sensitivity set at the time of teaching.
E3X-N
Procedure
1
2
3
4
5
6
7
2. Channels (E3X-NM) are selected in the following order.
When all the channels are selected, it is possible to set the sensitivity of the E3X-NM on all channels.
1 CH
adjust the optical axes so that the tip of the emitting fiber will be lit. If
the optical axes are divergent, the tip of the emitting fiber will flash
and the built-in buzzer of the E3X-Nj will beep.
Operation
Locate the sensor head within the rated sensing range with the
E3X-Nj.
Set the mode selector to TEACH.
The flashing function of the E3X-Nj will be activated. Therefore,
Locate a sensing target in the sensing area and press the teaching
button once. In the case of the E3X-NM, select a channel with the
channel selector and press the teaching button, at which time the
stability indicator for the selected channel will flash.
Through-beam Model
The teaching indicator (red) is lit.
The built-in buzzer beeps once.
Move the object and press the teaching button.
Through-beam Model
If teaching is OK:
If teaching is NG:
Change the position of the object and the sensing distance that have
been set and repeat from the beginning.
Set the mode selector to RUN to complete the sensitivity setting.
The teaching indicator (green) is OFF.
Select the logical output required with the operation mode selector.
Light is received.
Light is in-
terrupted.
2 CH
ALL
3 CH
The teaching indicator (red) turns green.
The built-in buzzer beeps once.
The teaching indicator (red) starts flashing.
The operation indicator also starts flashing.
(E3X-NM)
The built-in buzzer beeps 3 times.
Reflective Model
Reflective Model
Base
Base
4 CH
Mark
7
Mark
Reflective Model
Reflective Model
E3X-NT
---
---
TEACH
TEACH
TEACH
TEACH
RUN
RUN
L
D
ON
ON
E3X-NM
L ON
D ON
TEACH
TEACH
CH
TIMER
TIMER
RUN
RUN
SET
SET
TEACH
1
TEACH
2 3 4
E3X-N