71M6511H-IGT/F Maxim Integrated Products, 71M6511H-IGT/F Datasheet - Page 34

IC ENERGY METER RESIDENT 64-LQFP

71M6511H-IGT/F

Manufacturer Part Number
71M6511H-IGT/F
Description
IC ENERGY METER RESIDENT 64-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 71M6511H-IGT/F

Processor Series
6511x
Core
80515
Data Bus Width
8 bit
Program Memory Type
Flash
Program Memory Size
64 KB
Data Ram Size
7 KB
Interface Type
I2C, SSI, UART
Maximum Clock Frequency
5 MHz
Number Of Programmable I/os
12
Number Of Timers
2
Operating Supply Voltage
3 V to 3.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
LQFP-64
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Development Tools By Supplier
71M6511H-DB
Minimum Operating Temperature
- 40 C
On-chip Adc
22 bit Delta Sigma
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6511H-IGT/F
Manufacturer:
PERICOM
Quantity:
1 200
Part Number:
71M6511H-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Interrupt Priority Level Structure
All interrupt sources are combined in groups, as shown in Table 46:
Each group of interrupt sources can be programmed individually to one of four priority levels by setting or clearing one bit in
the special function register IP0 and one in IP1. If requests of the same priority level are received simultaneously, an internal
polling sequence as per Table 50 determines which request is serviced first.
IEN enable bits must be set to permit any of these interrupts to occur. Likewise, each interrupt has its own flag bit that is set by
the interrupt hardware and is reset automatically by the MPU interrupt handler (0 through 5). XFER_BUSY and RTC_1SEC,
which are OR-ed together, have their own enable and flag bits in addition to the interrupt 6 enable and flag bits (see Table 45),
and these interrupts must be cleared by the MPU software.
An overview of the interrupt structure is given in Figure 7.
Interrupt Priority 0 Register (IP0)
Interrupt Priority 1 Register (IP1)
Page: 34 of 98
Group
IP1.x
0
1
2
3
4
5
A Maxim Integrated Products Brand
MSB
MSB
Serial channel 0 interrupt
External interrupt 0
External interrupt 1
IP0.x
Timer 0 interrupt
Timer 1 interrupt
--
-
-
Priority Level
WDTS
Note: WDTS is not used for interrupt controls
-
© 2005–2010 Teridian Semiconductor Corporation
0
0
1
1
IP0.5
IP1.5
Table 46: Priority Level Groups
Serial channel 1 interrupt
Table 47: The IP0 Register:
Table 48: The IP1 Register:
Table 49: Priority Levels
IP0.4
IP1.4
0
1
0
1
-
-
-
-
-
IP0.3
IP1.3
Single-Phase Energy Meter IC
Level0 (lowest)
Level1
Level2
Level3 (highest)
IP0.2
IP1.2
71M6511/71M6511H
External interrupt 2
External interrupt 3
External interrupt 4
External interrupt 5
External interrupt 6
DATA SHEET
IP0.1
IP1.1
LSB
LSB
IP0.0
IP1.0
NOVEMBER 2010
V2.7

Related parts for 71M6511H-IGT/F