EM260-USART-JMP-R Ember, EM260-USART-JMP-R Datasheet - Page 31

KIT JUMP START FOR EM260

EM260-USART-JMP-R

Manufacturer Part Number
EM260-USART-JMP-R
Description
KIT JUMP START FOR EM260
Manufacturer
Ember
Series
JumpStartr
Type
802.15.4/Zigbeer

Specifications of EM260-USART-JMP-R

Frequency
2.4GHz
For Use With/related Products
EM260
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
636-1004
EM260-JMP
1. Activate Slave Select (nSSEL).
2. Transmit the appropriate command:
3. Wait for nHOST_INT to assert.
4. Transmit and receive 0xFF until a byte other than 0xFF is received.
5. Receive response 0xFE (a byte other than 0xFF) and read the next byte for a length.
6. Stop transmitting after the number of bytes (length) is received plus the Frame Terminator.
7. Decode the response:
8. Deactivate Slave Select.
5.7.3
1. nHOST_INT asserts.
2. Activate Slave Select (nSSEL).
0xFE - SPI Byte indicating an EZSP Frame
0x02 - Length Byte showing the EZSP Frame is 2 bytes long
0x00 - EZSP Frame Control Byte indicating a command with no sleeping
0x05 - EZSP Frame Type Byte indicating the
0xA7 - Frame Terminator
0xFE - SPI Byte indicating an EZSP Frame
0x02 - Length Byte showing the EZSP Frame is 2 bytes long
0x80 - EZSP Frame Control Byte indicating a response with no overflow
0x05 - EZSP Frame Type Byte indicating the NOP response
0xA7 - Frame Terminator
EM260 Reset
Figure 10. EM260 Reset Example
NOP
command
120-1003-000D
EM260
31

Related parts for EM260-USART-JMP-R